COMPONENTS OF STRUCTURED CABLING SYSTEMS

   


Patch Panels

Work Area Outlets

Keystone Jacks

Modular Plugs

Cross Connection

Fiber Optic

Cable Managers

Patch Cords

Cables

Twisted pair cable

Indoor, unshielded
UTP solid, 4 pairs, cat. 6, PVC
UTP patch, 4 pairs, cat. 6, PVC
UTP patch, 4 pairs, cat. 6, with spacer, PVC
UTP solid, 4 pairs, cat. 6, LSZH
UTP solid, 4 pairs, cat. 6 Plenum
UTP solid, 2 pairs, cat. 5, PVC
UTP solid, 2 pairs, cat. 5, LSZH
UTP solid, 4 pairs, cat. 5e, PVC
UTP solid, 4 pairs x 2, cat. 5e, PVC
UTP patch, 4 pairs, cat. 5e, PVC
UTP solid, 4 pairs, cat. 5e, LSZH
UTP solid, 4 pairs, cat. 5e, Plenum
UTP patch, 1 pair, cat. 5e, PVC
UTP solid 1 pair, cat. 5e, cross
UTP patch, 2 pairs, cat. 5e, PVC
UTP solid, 10/25/50/100 pairs, cat. 3, PVC
UTP solid, 25/50/100 pairs, cat. 5, PVC
UTP solid, 12/16/24/48/100 pairs, cat. 5, PVC
UTP solid, 8/10/12/16 pairs, cat. 5, PVC
UTP solid, 24 pairs, cat. 6, FR-PVC
UFTP solid, 24 pairs, cat. 6a, FR-LSZH
UTP solid, 25 pairs(4x6+1), cat. 5, PVC
Indoor, shielded
SSTP solid, 4 pairs, cat. 7a (10 GBE),
FR-LSZH

FFTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
SSTP solid, 4 pairs, cat. 7 (1200 MHz), LSZH
SSTP solid, 4 pairs, cat. 7 (1200 MHz), FR-PVC
SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-PVC
SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-LSZH
SSTP patch, 4 pairs, cat. 7 (600 MHz), LSZH
FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC-R
SFTP solid, 4 pairs, cat. 6a(10 GBE), FR-LSZH
SFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
UFTP solid, 4 pairs, cat. 6, FR-LSZH
USTP solid, 4 pairs, cat. 6a
SSTP solid, 4 pairs, cat. 6
SSTP patch, 4 pairs, cat. 6
STP solid, 4 pairs, cat. 6, PVC
STP patch, 4 pairs, cat. 6
FTP solid, 4 pairs, cat. 6, PVC
FTP solid, 4 pairs, cat. 5e
FTP solid, 4 pairs, cat. 5e LSZH
FTP patch, 4 pairs, cat. 5e
SFTP solid, 4 pairs, cat. 5e
SFTP patch, 4 pairs, cat. 5e
FTP solid, 2 pairs, cat. 5
FTP solid, 2 pairs, cat. 5, LSZH
FTP solid, 10/25/50/100 pairs, cat. 3
FTP solid, 25 pairs, cat. 5
FTP solid, 24/48/100 pairs, cat. 5e
SSTP solid, 24 pairs, cat. 7
FTP solid, 50 pairs, cat. 5
Outdoor, unshielded
USTP solid, 4 pairs, cat. 6a
UTP solid, 4 pairs, cat. 6
UTP solid, 4 pairs, cat. 5e
UTP solid, 4 pairs, cat. 5e, with messenger
UTP solid, 2 pairs, cat. 5
UTP solid, 2 pairs, cat. 5, with messenger
UTP solid, 25/50/100 pairs, cat. 5
UTP solid, 10/25/50/100 pairs, cat. 3
UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
UTP solid, 10/25/50/100 pairs, cat. 3, armored
UTP solid, 25 pairs(4x6+1), cat. 5, PE
Outdoor, shielded
SSTP solid, 4 pairs, cat. 7, 10GBE
SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
SSTP solid, 4 pairs, cat. 7
STP solid, 4 pairs, cat. 6, FR-LSZH
STP solid, 4 pairs, cat. 6, FR-PVC
STP solid, 4 pairs, cat. 6
FTP solid, 4 pairs, cat. 5e
FTP solid, 4 pairs, cat. 5e, with messenger
FTP solid, 25 pairs, cat. 5
FTP solid, 2 pairs, cat. 5
FTP solid, 2 pairs, cat. 5, with messenger
FTP solid, 10/25/50/100 pairs, cat. 3
FTP solid, 10/25 pairs, cat. 3, with messenger


Fiber-optic

Indoor
Zip-cord
With tight buffer
Multi loose tube
Indoor/outdoor
With tight buffer
Multi loose tube
Outdoor
Single loose tube
Multi loose tube, with messenger
With tight buffer, with steel armored band
Single loose tube, with steel armored band
Multi loose tube, with steel armored band
Multi loose tube, with steel armored wire

Telephone cable

UTC solid, 10/25/50/100 pairs, cat. 2
UTC stranded (patch), 4 wires, cat. 2

Hybrid cable

Multiservice
Video- and control
Indoor
Outdoor, armored

Coaxial cable

type RG-6
COAX-RG6
COAX-RG6-CU
COAX-RG6-OUTDOOR/LSZH
COAX-RG6-SW-OUTDOOR
type RG-8
COAX-RG8
type RG-11
COAX-RG11
type RG-58
COAX-RG58
type RG-59
COAX-RG59
COAX-RG59-CU
COAX-RG59-OUTDOOR/LSZH
COAX-RG59-SW-OUTDOOR
type RG-213
COAX-RG213
SAT703N, 75 Ohm
COAX-SAT703N
Camera cable
RG 59, 75 Ohm, 2 x 0.5 mm
RG 59, 75 Ohm, 2 x 0.75 mm

Industrial cable

Industrial Ethernet
Shielded
FTP, 4 pairs, cat.5e, solid
SFTP, 2 pairs, cat.5e, solid
SFTP, 4 pairs, cat.5e, solid
SFTP, 2 pairs, cat.5e, stranded (patch)
SFTP, 4 pairs, cat.5e, stranded (patch)
SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
SFTP, 2 pairs, cat.5e, solid
SFTP, 4 pairs, cat.5e, solid
SFTP, 2 pairs, cat.5e, stranded (patch)
SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
UTP, 2 pairs, cat.5e, solid
UTP, 4 pairs, cat.5e, solid
UTP, 4 pairs, cat.5e, solid, outdoor
UTP, 2 pairs, cat.5e, stranded (patch)
UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
UTP, 2 pairs, cat.5e, solid
UTP, 4 pairs, cat.5e, solid
UTP, 2 pairs, cat.5e, stranded (patch)
UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
RS-485, 1 pair
RS-422/485, 2 pairs
RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
RS-485, 1 pair
RS-422/485, 2 pairs
RS-422/485, 3 pairs
RS-422/485, 4 pairs
In double PVC jacket, armored
RS-422/485, 2 pairs, every pair is separately shielded
RS-422/485, 3 pairs, every pair is separatly shielded
RS-422/485, 4 pairs, every pair is separatly shielded
RS-422/485, 8 pairs, every pair is separatly shielded
RS-422/485, 2 pairs, common shield
ProfiBus
SFTP, 1 pair, solid, PVC jacket
SFTP, 1 pair, solid, polyethylene jacket
SFTP, 1 pair, solid, polyurethane jacket
SFTP, 1 pair, solid, PVC and polyethylene jackets
SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
FC-SFTP, 1 pair, solid, PVC jacket
FC-SFTP, 1 pair, solid, polyethylene jacket
FTP, 1 pair, stranded (patch), PVC jacket
PA-STP, 1 pair, stranded (patch), PVC jacket
SFTP, 1 pair, stranded (patch), polyurethane jacket
SFTP, 1 pair, stranded (patch), FR-LSZH
L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH

Installation Accessories

Tools

Racks and Cabinets

Power Distribution Units

Access Floors

Axelent Cable Trays

Wire Mesh Cable Trays

Production Shutdown




Catalog

Twisted Pair Cable SFTP, category 6a (10GBE), 4 pairs, solid, FR-LSZH jacket


Twisted Pair Cable SFTP, category 6a (10GBE), 4 pairs, solid, FR-LSZH jacket

Specifications:
Meets IEC 61156, ISO/IEC 11801 and TIA/EIA-568B requirements
Fire protection - CM
The cable meets IEC 60332-1, UL 1581 VW-1 fire safety standard

Description:
Copper cable, 4 pairs, category 6a, solid
The cable contains 4 twisted pairs. Each pair is individually aluminum-foil shielded and cabled together with a drain-wire, overall wire braid shielded and covered with FR-LSZH jacket
The cable is used for indoor installation

Materials:
Conductive material: bare copper
Conductor insulation: foam polyolefin
The cable jacket: fire retardant low smoke zero halogen compound (FR-LSZH)
Shield: each pair is individually shielded (from outside) with aluminum-polyether foil, ensuring 100% coverage of the twisted pair
Overall shield: tinned copper wire braid, braid coating density 52%

Technical characteristics:
Conductor diameter (core): 0.51 mm (24 AWG)
Conductor outer diameter (with jacket): 1.03 mm
Cable outer diameter: 6.7 mm
Cable weight per 1 km: 45 kg
Standard package: 500 m

Electrical characteristics:
Frequency, MHz Attenuation, dB/100m 20°C PS NEXT Loss, dB NEXT Loss, dB RL, dB PS ANEXT, dB PS ELFEXT, dB
Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A
1 3.0 3.1 95.0 72.3 98.0 75.3 22.0 20.0 70.0 67.0 85.0 65.0
4 5.6 5.8 95.0 63.3 98.0 66.3 25.0 23.0 70.0 67.0 73.0 53.0
10 8.7 9.0 95.0 57.3 98.0 60.3 28.0 25.0 70.0 67.0 65.0 45.0
20 12.4 12.8 90.0 52.8 93.0 55.8 28.0 25.0 70.0 67.0 59.0 39.0
30 15.3 15.8 85.0 50.1 88.0 53.1 27.0 23.8 70.0 67.0 55.4 35.4
100 29.0 29.9 80.0 42.3 83.0 45.3 24.0 21.1 67.0 62.5 45.0 25.0
150 36.2 37.4 78.0 39.7 81.0 42.7 22.0 18.8 66.0 59.8 41.5 21.5
200 42.5 43.8 78.0 37.8 81.0 40.8 21.0 18.0 65.0 58.0 49.0 19.0
250 48.2 49.7 75.0 36.3 78.0 39.3 20.0 17.3 63.0 56.5 37.0 17.0
300 53.4 55.1 75.0 35.1 78.0 38.1 19.0 17.3 62.0 55.3 35.5 15.5
400 63.1 65.1 70.0 33.3 73.0 36.3 19.0 17.3 61.0 53.4 33.0 13.0
500 71.9 74.0 70.0 31.8 73.0 34.8 19.0 17.3 59.0 52.0 31.0 11.0
600 80.0 - 70.0 - 73.0 - 19.0 - 57.0 - 30.0 -
700 87.7 - 70.0 - 73.0 - 19.0 - 55.0 - 29.0 -

Frequency 1 - 500 MHz
Impedance 100 Ω
Direct current conductor resistance 97 Ω/km
Max Resistance Unbalance 2 %
Capacitance 1,2 pF/m
Propagation velocity 78 %
Dielectric breakdown strength 700 V/1 min
Min. insulation resistance 5 G•km
Tension force 100 N
Minimum bend radius 45 mm
Operating temperature -30°C - +65°C

Ordering:
SFTP4-C6a-SOLID-INDOOR-LSZH Twisted Pair Cable SFTP, category 6a (10GBE), 4 pairs, solid, FR-LSZH

 
e-mail: info@hyperline.com
Copyright © 2003-2012 HYPERLINE® Registered Trade-mark; used under license

TERMS AND CONDITIONS OF SALE
Rambler's Top100