Outdoor fiber optic cable, with tight buffer, armored with steel band, waterproof
 |
1 – Jacket
2 – Protective skin
3 – Armored jacket
4 – Rip-cord
5 – Hydrophobous extender
6 – Fiber optic
7 – Main load-bearing element
|
Specifications
The cable meets EIA/TIA-455, IEC- 60794, IEC-60794 and EIA/TIA FOTP 82B
Optical characteristics meet ISO/IEC 11801
The cable meets the requirements for IEC 60332-1 fire safety standard
|
Description
Fiber optic cable, with tight buff er, 2 – 72 fibers, armored with steel band, waterproof
The cable is used for the outdoor cabling and SCS building
The cable may be installed in cable ducts and is suitable for underground cabling
|
Materials
Conductive material: optical fiber 9/125, 50/125, 62.5/125
Fiber insulation: polybutylene terephthalate module (loose tube)
Armoring and waterproofi ng: waterblocking aramid strength yarns
Outer sheathing: UV-resistant polyethylene
Armor: corrugated steel band
|
Technical characteristics
| Fiber diameter |
125 ± 1μm |
| The insulated fiber diameter |
242 ± 7μm |
| Fiber jacket diameter |
0.9 mm (0.03") |
| Cable outer diameter |
11/11.2/12.2/15.5 mm (0.43/0.44/0.48/0.61") |
| Fiber jacket tensile strength |
1.3-8.9 N |
| Fiber jacket out-of-roundness |
1% or less |
| Minimum bend radius |
220/230/244/310 mm (8.66/9.05/9.61/12.20") |
| Tension force (cabling) |
2 700 N |
| Tension force (operation) |
1 600 N |
| Crushing force |
800 N/cm (24384 N/ft) |
| Repeated impact resistance |
N = 20 |
| Flexing resistance |
25 cycles |
| Cabling temperature |
-20°C – +70°C (-4°F – +158°F) |
| Operation temperature |
-40°C – +70°C (-40°F – +158°F) |
| Storage temperature |
-40°C – +70°C (-40°F – +158°F) |
| Weight of 1 km of cable |
135/140/160/252 kg (297.62/308.65/352.74/555.57 lbs) |
| Standard bunch |
1000 m (3280.84 ft) |
Ordering:
| FO-AD-OUT-XX-YY-ARM |
Outdoor fiber optic cable, with tight buffer, armored with steel band, waterproof |
| *XX – 50 – fiber 50/125; 62 – fiber 62.5/125; 9 – fiber 9/125; YY – number of fibers from 2 to 72 |
|
|