Catalog

Shielded Twisted Pair Cable (FTP), 24/48/100 pairs, Category 5e, Solid, Indoor

Kabel typu skrętka ekranowana FTP, category 5e, 24/48/100 pairs, jednozylowy (solid)
Specifications:
Meets ANSI/EIA/TIA 568-A, ISO/IEC 11801 and IEC 61156-6 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard

Description:
Shielded Copper cable, 24/48/100 pairs, category 5e, solid. Cable consists of shielded
FTP bunches of 4 pairs each
Shield: aluminum foil
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC
An aluminum tape shield is helically applied over the cable core with a minimum
overlap of 25% or 5 mm (0.19"), thickness – 0.025 mm (0.001"), width – 20 mm (0.78")


24 pairs


1 – Jacket
2 – Protective skin
3 – Bunch of 4 solid twisted pairs
4 – Shield-foil
5 – Drain wire
6 – Solid twisted pair
7 – Main load-bearing element

Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 1 mm (0.04")
Outer cable diameter: 20 mm (0.78")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Rip cord has a breaking strength of 10 kg (98 N)
Conductor elongation: 14% minimum
Drain wire diameter: 0.5 mm (0.019")
Pulling strength: 400 N
Breaking strength: 600 N
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft (304.8 m): 100.3 kg (221.1 lbs)
Standard package: 1000 m (3280 ft)

Electrical characteristics:
Frequency, MHz Max attenuation, dB/100m (dB/100ft) PP-NEXT Min. dB PS-NEXT Min., dB ALIEN PS-NEXT, Min., dB PdB/100m (dB/100ft)in. dB/100m PS-ACR Min. dB/100m (dB/100ft) PP-ELFEXT Min. dB/100m (dB/100ft) PS-ELFEXT Min., dB/100m (dB/100ft) RL Min., dB
1.0 2.0 (0.6) 65.3 62.3 65.0 63.3 (19.29) 60.3 (18.38) 64.8 (19.75) 61.8 (18.84) 20.0
4.0 4.1 (1.25) 56.3 53.3 59.3 52.2 (15.91) 49.2 (15.00) 52.7 (16.06) 49.7 (15.15) 23.0
8.0 5.8 (1.80) 51,8 48.8 54.8 46.0 (14.02) 43.0 (13.11) 46.7 (14.23) 43.7 (13.32) 24.5
10.0 6.5 (1.98) 50.3 47.3 53.3 43.8 (13.35) 40.8 (12.43) 44.8 (13.65) 41.8 (12.74) 25.0
16.0 8.2 (2.5) 47.3 44.3 50.3 39.1 (11.92) 36.1 (11.00) 40.7 (12.40) 37.7 (11.49) 25.0
20.0 9.3 (2.8) 45.8 42.8 48.8 36.5 (11.12) 33.5 (10.21) 38.7 (11.79) 35.7 (10.88) 25.0
25.0 10.4 (3.2) 44.3 41.3 47.3 33.9 (10.33) 30.9 (9.42) 36.8 (11.22) 33.8 (10.30) 24.3
31.25 11.7 (3.6) 42.9 39.9 45.9 31.2 (9.51) 28.2 (8.59) 34.9 (10.64) 31.9 (9.72) 23.6
62.5 17.0 (5.2) 38.4 35.4 41.4 21.4 (6.52) 18.4 (5.61) 28.8 (8.78) 25.8 (7.86) 21.5
100.0 22.0 (6.7) 35.3 32.3 38.3 13.3 (4.05) 10.3 (3.14) 24.8 (7.56) 21.8 (6.64) 20.1
160.0 28.6 (8.72) 32.3 29.3 35.3 3.7 (1.13) 0.70 (0.21) 20.7 (6.31) 17.7 (5.39) 18.6
200.0 32.3 (9.84) 30.7 27.7 33.7 -1.6 (-0.49) -4.6 (-1.40) 18.7 (5.70) 15.7 (4.78) 18.0



48 pairs


1 – Jacket
2 – Protective skin
3 – Bunch of 4 solid twisted pairs
4 – Shield-foil
5 – Drain wire
6 – Solid twisted pair
7 – Main load-bearing element

Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 1 mm (0.04")
Outer cable diameter: 26 mm (1.02")
Jacket thickness: 1.2 mm (0.047")
Minimum bend radius: 10 outer cable diameters
Rip cord has a breaking strength of 10 kg (98 N)
Conductor elongation: 14% minimum
Drain wire diameter: 0.5 mm (0.019")
Pulling strength: 400 N
Breaking strength: 600 N
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft (304.8 m): 196.5 kg (373.6 lbs)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Frequency, MHz Max attenuation, dB/100m (dB/100ft) PP-NEXT Min. dB PS-NEXT Min., dB PP-ELFEXT Min. dB/100m (dB/100ft) PS-ELFEXT Min., dB/100m (dB/100ft) RL Min., dB
1 2 (0.6) 66 63 64 (19.50) 61 (18.59) 20
4 4 (1.22) 57 54 52 (15.85) 49 (14.93) 23
10 6.3 (1.92) 51 49 44 (13.41) 41 (12.50) 25
16 8 (2.44) 48 45 40 (12.19) 37 (11.28) 25
20 9 (2.74) 47 44 38 (11.58) 35 (10.67) 25
30 11.2 (3.41) 44 41 34 (10.36) 41 (12.50) 24
31.25 11.4 (3.47) 44 41 34 (10.36) 31 (9.45) 24
62.5 16.5 (5.03) 39 36 28 (8.53) 25 (7.62) 21.5
100 21.3 (6.49) 36 33 24 (7.31) 21 (6.40) 20.5



100 pairs


1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Bunch of 4 solid twisted pairs
5 – Shield-foil
6 – Drain wire
7 – Solid twisted pair
8 – Main load-bearing element

Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 1 mm (0.04")
Outer cable diameter: 38.8 mm (1.52")
Jacket thickness: 1 mm (0.039")
Minimum bend radius: 10 outer cable diameters
Rip cord has a breaking strength of 10 kg (98 N)
Conductor elongation: 14% minimum
Drain wire diameter: 0.5 mm (0.019")
Pulling strength: 400 N
Breaking strength: 600 N
Operating temperature: 0°C – +50°C (+32°F – +122°F)
Weight per 1000 ft (304.8 m): 196.5 kg (373.6 lbs)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Frequency, MHz Max attenuation, dB/100m (dB/100ft) PP-NEXT Min. dB PS-NEXT Min., dB PP-ELFEXT Min. dB/100m (dB/100ft) PS-ELFEXT Min., dB/100m (dB/100ft) RL Min., dB
1 2 (0.6) 66 63 64 (19.50) 61 (18.59) 20
4 4 (1.22) 57 54 52 (15.85) 49 (14.93) 23
10 6.3 (1.92) 51 49 44 (13.41) 41 (12.50) 25
16 8 (2.44) 48 45 40 (12.19) 37 (11.28) 25
20 9 (2.74) 47 44 38 (11.58) 35 (10.67) 25
30 11.2 (3.41) 44 41 34 (10.36) 41 (12.50) 24
31.25 11.4 (3.47) 44 41 34 (10.36) 31 (9.45) 24
62.5 16.5 (5.03) 39 36 28 (8.53) 25 (7.62) 21.5
100 21.3 (6.49) 36 33 24 (7.31) 21 (6.40) 20.5


Twisted Pair Cable FTP 24 pairs 48 pairs 100 pairs
Max DC Resistance at 20°C (68°F) 94.8 Ohm/km
(152.57 Ohm/mile)
94 Ohm/km (151.28 Ohm/mile)
(151.28 Ohm/mile)
Max Resistance Unbalance 3% 2% max.
Characteristic Impedance at 1-100 MHz 100 ± 15 Ohm
Capacitance at 1 kHz 50 ± 4 pF/m (15.2 ± 1.22 pF/ft)
Max Capacitance unbalance at 1kHz 1.6 pF/m (0.49 pF/ft)
Longitudinal Conversion Loss at 1-30 MHz 46-10*Log(f) dB

Nominal Velocity of Propagation

0.68-0.70
Max . Voltage rating 220 V
Dielectric Strength of Insulation 100 Vac/1 min 700 Vac/1 min
Max. Propagation Delay
At 1 MHz
At 10 MHz
At 100 MHz

5.7 ns/m (1.74 ns/ft)
5.4 ns/m (1.64 ns/ft)
5.3 ns/m (1.61 ns/ft)
Propagation Delay Skew at 1-100 MHz 15 ns/100 m
(4.57 ns/100 ft)
Insulation Resistance at 500 V 5 GOhm*km
(3.11 GOhm*mile)
Transfer Impandence
At 1 MHz
At 10 MHZ

nom. 12, max. 50 MOhm/m (15.24 MOhm/ft)
nom.16 max. 100 MOhm/m (30.48 MOhm/ft)
Coupling attenuation at 1-100 MHz 65 dB 40 dB

Ordering:
FTPXX-C5E-SOLID-INDOOR Shielded Twisted Pair Cable FTP, category 5e, 24/48/100 pairs, solid

XX – quantity of pairs: 24, 48, 100 pairs