 |
COMPONENTS OF STRUCTURED CABLING SYSTEMS |
 |
|
| |
Patch Panels
Work Area Outlets
Keystone Jacks
Modular Plugs
Cross Connection
Fiber Optic
Cable Managers
Patch Cords
Cables
Twisted pair cable
Indoor, unshielded
• UTP solid, 4 pairs, cat. 6, PVC
• UTP patch, 4 pairs, cat. 6, PVC
• UTP patch, 4 pairs, cat. 6, with spacer, PVC
• UTP solid, 4 pairs, cat. 6, LSZH
• UTP solid, 4 pairs, cat. 6 Plenum
• UTP solid, 2 pairs, cat. 5, PVC
• UTP solid, 2 pairs, cat. 5, LSZH
• UTP solid, 4 pairs, cat. 5e, PVC
• UTP solid, 4 pairs x 2, cat. 5e, PVC
• UTP patch, 4 pairs, cat. 5e, PVC
• UTP solid, 4 pairs, cat. 5e, LSZH
• UTP solid, 4 pairs, cat. 5e, Plenum
• UTP patch, 1 pair, cat. 5e, PVC
• UTP solid 1 pair, cat. 5e, cross
• UTP patch, 2 pairs, cat. 5e, PVC
• UTP solid, 10/25/50/100 pairs, cat. 3, PVC
• UTP solid, 25/50/100 pairs, cat. 5, PVC
• UTP solid, 12/16/24/48/100 pairs, cat. 5, PVC
• UTP solid, 8/10/12/16 pairs, cat. 5, PVC
• UTP solid, 24 pairs, cat. 6, FR-PVC
• UFTP solid, 24 pairs, cat. 6a, FR-LSZH
• UTP solid, 25 pairs(4x6+1), cat. 5, PVC
Indoor, shielded
• SSTP solid, 4 pairs, cat. 7a (10 GBE), FR-LSZH
• FFTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), FR-PVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-PVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-LSZH
• SSTP patch, 4 pairs, cat. 7 (600 MHz), LSZH
• FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
• FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC-R
• SFTP solid, 4 pairs, cat. 6a(10 GBE), FR-LSZH
• SFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
• UFTP solid, 4 pairs, cat. 6, FR-LSZH
• USTP solid, 4 pairs, cat. 6a
• SSTP solid, 4 pairs, cat. 6
• SSTP patch, 4 pairs, cat. 6
• STP solid, 4 pairs, cat. 6, PVC
• STP patch, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 6, PVC
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e LSZH
• FTP patch, 4 pairs, cat. 5e
• SFTP solid, 4 pairs, cat. 5e
• SFTP patch, 4 pairs, cat. 5e
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, LSZH
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 25 pairs, cat. 5
• FTP solid, 24/48/100 pairs, cat. 5e
• SSTP solid, 24 pairs, cat. 7
• FTP solid, 50 pairs, cat. 5
Outdoor, unshielded
• USTP solid, 4 pairs, cat. 6a
• UTP solid, 4 pairs, cat. 6
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e, with messenger
• UTP solid, 2 pairs, cat. 5
• UTP solid, 2 pairs, cat. 5, with messenger
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• UTP solid, 10/25/50/100 pairs, cat. 3, armored
• UTP solid, 25 pairs(4x6+1), cat. 5, PE
Outdoor, shielded
• SSTP solid, 4 pairs, cat. 7, 10GBE
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
• SSTP solid, 4 pairs, cat. 7
• STP solid, 4 pairs, cat. 6, FR-LSZH
• STP solid, 4 pairs, cat. 6, FR-PVC
• STP solid, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e, with messenger
• FTP solid, 25 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 10/25 pairs, cat. 3, with messenger
Fiber-optic
Indoor
• Zip-cord
• With tight buffer
• Multi loose tube
Indoor/outdoor
• With tight buffer
• Multi loose tube
Outdoor
• Single loose tube
• Multi loose tube, with messenger
• With tight buffer, with steel armored band
• Single loose tube, with steel armored band
• Multi loose tube, with steel armored band
• Multi loose tube, with steel armored wire
Telephone cable
• UTC solid, 10/25/50/100 pairs, cat. 2
• UTC stranded (patch), 4 wires, cat. 2
Hybrid cable
• Multiservice
• Video- and control
• Indoor
• Outdoor, armored
Coaxial cable
type RG-6
• COAX-RG6
• COAX-RG6-CU
• COAX-RG6-OUTDOOR/LSZH
• COAX-RG6-SW-OUTDOOR
type RG-8
• COAX-RG8
type RG-11
• COAX-RG11
type RG-58
• COAX-RG58
type RG-59
• COAX-RG59
• COAX-RG59-CU
• COAX-RG59-OUTDOOR/LSZH
• COAX-RG59-SW-OUTDOOR
type RG-213
• COAX-RG213
SAT703N, 75 Ohm
• COAX-SAT703N
Camera cable
• RG 59, 75 Ohm, 2 x 0.5 mm
• RG 59, 75 Ohm, 2 x 0.75 mm
Industrial cable
Industrial Ethernet
Shielded
• FTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid, outdoor
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 3 pairs
• RS-422/485, 4 pairs
In double PVC jacket, armored
• RS-422/485, 2 pairs, every pair is separately shielded
• RS-422/485, 3 pairs, every pair is separatly shielded
• RS-422/485, 4 pairs, every pair is separatly shielded
• RS-422/485, 8 pairs, every pair is separatly shielded
• RS-422/485, 2 pairs, common shield
ProfiBus
• SFTP, 1 pair, solid, PVC jacket
• SFTP, 1 pair, solid, polyethylene jacket
• SFTP, 1 pair, solid, polyurethane jacket
• SFTP, 1 pair, solid, PVC and polyethylene jackets
• SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
• FC-SFTP, 1 pair, solid, PVC jacket
• FC-SFTP, 1 pair, solid, polyethylene jacket
• FTP, 1 pair, stranded (patch), PVC jacket
• PA-STP, 1 pair, stranded (patch), PVC jacket
• SFTP, 1 pair, stranded (patch), polyurethane jacket
• SFTP, 1 pair, stranded (patch), FR-LSZH
• L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH
Installation Accessories
Tools
Racks and Cabinets
Power Distribution Units
Access Floors
Axelent Cable Trays
Wire Mesh Cable Trays
Production Shutdown
|
|
Twisted Pair Cable (FTP), 4 pairs, Category 6, Solid, PVC
 |
1 - Copper Conductor
2 - HDPE Insulation
3 - Polyester
4 - Drain Wire
5 - Aluminum Foil
6 - Ripcord
7 - Jacket
8 - Separator
|
Specifications:
Meets TIA/EIA/ 568-B.2 requirements
Fire protection - CM
The cable meets UL 444 UL 1581 fire safety standard
|
Description:
Shielded Copper cable, 4 pairs (separated), category 6, solid, with drain wire
Application: Horizontal communication cable
Cable is used for indoor installation
|
Materials:
Conductive material: wire made of annealed bare copper
Conductor insulation: HDPE
Shield: an aluminum-mylar (aluminum-polyethyleneterephthalate) tape is helically applied over the cable core, tape thickness - 0.001" (0.025 mm), width - 0.709" (18 mm); shield thickness - 0.016" (0.04 mm)
Drain wire: tinned copper
The cable jacket: PVC
|
Technical characteristics:
Conductor diameter: 0.57 mm (0.022") (23 AWG)
Insulated conductor diameter: 1.09 ± 0.06 mm (0.043" ± 0.002")
Drain wire diameter: 0.53 mm (0.021")
Outer cable diameter: 7.2 ± 0.3 mm (0.276" ± 0.012")
Jacket thickness: 0.55 mm (0.028")
Shield thickness: 0.04 mm (0.016")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 15% minimum
Operating temperature: -20°C - +75°C (-4°F - +167°F)
Rip cord has a breaking strength of 6.9 kg (60 N)
Standard package: 305 m (1000.66 ft)
Weight per 1000 ft (304.8 m): 16.8 kg (37.04 lbs)
|
Electrical characteristics
| Frequency, MHz |
RL |
Attenuation, dB |
NEXT, dB |
PSNEXT, dB |
ELFEXT, dB |
PSELFEXT, dB |
| 1.0 | 20.0 | 1.9 | 74.3 | 72.3 | 67.8 | 64.8 |
| 4.0 | 23.0 | 3.7 | 65.3 | 63.3 | 61.8 | 52.8 |
| 8.0 | 24.5 | 5.3 | 60.3 | 58.8 | 55.7 | 46.7 |
| 10.0 | 25.0 | 5.9 | 59.3 | 57.3 | 53.8 | 44.8 |
| 16.0 | 25.0 | 7.5 | 56.3 | 54.3 | 49.7 | 40.7 |
| 20.0 | 25.0 | 8.4 | 54.8 | 52.8 | 47.8 | 38.7 |
| 25.0 | 24.3 | 9.5 | 53.4 | 51.4 | 45.8 | 36.8 |
| 31.25 | 23.6 | 10.6 | 51.9 | 49.9 | 43.9 | 34.9 |
| 62.5 | 21.5 | 15.4 | 47.4 | 45.4 | 37.9 | 28.8 |
| 100.0 | 20.1 | 19.8 | 44.3 | 42.3 | 33.8 | 24.8 |
| 155.00 | 18.8 | 25.1 | 41.4 | 39.4 | 27.8 | 20.9 |
| 200.00 | 18.0 | 29.0 | 39.8 | 37.8 | 25.8 | 18.7 |
| 250.00 | 17.3 | 32.8 | 38.3 | 36.6 | 24.3 | 16.8 |
| Max conductor resistance at 20°C (68°F) |
9.38 Ohm/100 m (2.86 Ohm/100 ft) |
| Max Resistance Unbalance |
5% |
| Max pair-to-ground capacitance unbalance |
330 pF/100 m (101 pF/100 ft) |
| Characteristic Impedance at 0.772-100 MHz |
100 ± 15 Ohm |
| Mutual capacitance |
5.6 nF/m (1.7 nF/ft) |
| Spark Test |
2.5 kV |
Ordering
| FTP4-C6-SOLID-INDOOR-PVC |
Shielded Twisted Pair Cable (FTP), 4 pairs, Category 6, Solid, Indoor, PVC |
|
|
| |
e-mail: info@hyperline.com Copyright © 2003-2012 HYPERLINE® Registered Trade-mark; used under license
|
TERMS AND CONDITIONS OF SALE |
 |
|
|