Shielded Twisted Pair Cable (FTP), category 5e, 4 pairs, Solid, LSZH

Shielded Twisted Pair Cable (FTP), category 5e, 4 pairs, Solid, LSZH

1 - Jacket
2 - Al-Mylar
3 - Drain
4 - Mylar Foil
5 - Solid twisted pair


Description:
Shielded Copper cable, 4 pairs, category 5e, solid
Application: horizontal communication cable
Cable is used for indoor installation
Meets UL444/UL1581 fire safety standard and TIA/EIA 568B.2

Technical characteristics:
Conductor: annealed bare copper 0.510.01 mm, 24 AWG Insulation: HDPE, minimum average thickness 0.19 mm, minimum thickness at any point 0.18 mm Insulated conductor diameter: 0.960.03 mm Identification:
  - Blue-White/Blue,
  - Orange-White /Orange,
  - Green-White/Green,
  - Brown-White/Brown
4 twisted pairs
Jacket: LSZH, minimum average thickness 0.450.05 mm, minimum thickness at any point 0.4 mm
Outer cable diameter: 6.30.3 mm
Minimum bend radius: 8xØ while installation, 6xØ while vertical cabling, 4xØ while horizontal cabling
Standard package: 18.5x37.5x36.5 cm (WxHxD) - 305 m
Weight of cable without package: 9.8 kg
Weight of cable with package: 10.5 kg
Weight per 1 km: 31.2 kg
Rating temp: 75°C
Flame test: CM
Standard: UL444/UL1581, TIA/EIA 568A

Electrical characteristics:
Frequency, MHz RL Attenuation, dB NEXT, dB PSNEXT, dB ELFEXT, dB PSELFEXT, dB
0.772   1.8 67.0 64.0    
1.0 20.0 2.0 65.3 62.3 63.8 60.8
4.0 23.0 4.0 56.3 53.3 51.7 48.7
8.0 24.5 5.8 51.8 48.8 45.7 42.7
10.0 25.0 6.5 50.3 47.3 43.8 40.8
16.0 25.0 8.2 47.3 44.3 39.7 36.7
20.0 25.0 9.3 45.8 42.8 37.7 34.7
25.0 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17.0 38.4 35.4 27.8 24.8
100.0 20.1 22.0 35.3 32.3 23.8 20.8


Conductor resistance at 20°C (68°F) 9.38 Ohm/100 m (2.9 Ohm/100 ft)
DC Resistance Unbalance 5%
Pair-to-Ground Capacitance Unbalance 330 pF/100 m (101 pF/100 ft)
Impedance 0.772-100 MHz 85-115 Ohm
Mutual Capacitance 5.6 nF/m (1.7 nF/ft)
Spark Test 2.5 kV


Ordering
FTP4-C5E-SOLID-LSZH Twisted Pair cable FTP, category 5e, 4 pairs, solid, LSZH