COMPONENTS OF STRUCTURED CABLING SYSTEMS |
 |
|
| |
Patch Panels
Work Area Outlets
Keystone Jacks
Modular Plugs
Cross Connection
Fiber Optic
Cable Managers
Patch Cords
Cables
Twisted pair cable
Indoor, unshielded
• UTP solid, 4 pairs, cat. 6, PVC
• UTP patch, 4 pairs, cat. 6, PVC
• UTP patch, 4 pairs, cat. 6, with spacer, PVC
• UTP solid, 4 pairs, cat. 6, LSZH
• UTP solid, 4 pairs, cat. 6 Plenum
• UTP solid, 2 pairs, cat. 5, PVC
• UTP solid, 2 pairs, cat. 5, LSZH
• UTP solid, 4 pairs, cat. 5e, PVC
• UTP solid, 4 pairs x 2, cat. 5e, PVC
• UTP patch, 4 pairs, cat. 5e, PVC
• UTP solid, 4 pairs, cat. 5e, LSZH
• UTP solid, 4 pairs, cat. 5e, Plenum
• UTP patch, 1 pair, cat. 5e, PVC
• UTP solid 1 pair, cat. 5e, cross
• UTP patch, 2 pairs, cat. 5e, PVC
• UTP solid, 10/25/50/100 pairs, cat. 3, PVC
• UTP solid, 25/50/100 pairs, cat. 5, PVC
• UTP solid, 12/16/24/48/100 pairs, cat. 5, PVC
• UTP solid, 8/10/12/16 pairs, cat. 5, PVC
• UTP solid, 24 pairs, cat. 6, FR-PVC
• UFTP solid, 24 pairs, cat. 6a, FR-LSZH
• UTP solid, 25 pairs(4x6+1), cat. 5, PVC
Indoor, shielded
• SSTP solid, 4 pairs, cat. 7a (10 GBE), FR-LSZH
• FFTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), FR-PVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-PVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-LSZH
• SSTP patch, 4 pairs, cat. 7 (600 MHz), LSZH
• FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
• FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC-R
• SFTP solid, 4 pairs, cat. 6a(10 GBE), FR-LSZH
• SFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
• UFTP solid, 4 pairs, cat. 6, FR-LSZH
• USTP solid, 4 pairs, cat. 6a
• SSTP solid, 4 pairs, cat. 6
• SSTP patch, 4 pairs, cat. 6
• STP solid, 4 pairs, cat. 6, PVC
• STP patch, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 6, PVC
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e LSZH
• FTP patch, 4 pairs, cat. 5e
• SFTP solid, 4 pairs, cat. 5e
• SFTP patch, 4 pairs, cat. 5e
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, LSZH
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 25 pairs, cat. 5
• FTP solid, 24/48/100 pairs, cat. 5e
• SSTP solid, 24 pairs, cat. 7
• FTP solid, 50 pairs, cat. 5
Outdoor, unshielded
• USTP solid, 4 pairs, cat. 6a
• UTP solid, 4 pairs, cat. 6
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e, with messenger
• UTP solid, 2 pairs, cat. 5
• UTP solid, 2 pairs, cat. 5, with messenger
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• UTP solid, 10/25/50/100 pairs, cat. 3, armored
• UTP solid, 25 pairs(4x6+1), cat. 5, PE
Outdoor, shielded
• SSTP solid, 4 pairs, cat. 7, 10GBE
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
• SSTP solid, 4 pairs, cat. 7
• STP solid, 4 pairs, cat. 6, FR-LSZH
• STP solid, 4 pairs, cat. 6, FR-PVC
• STP solid, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e, with messenger
• FTP solid, 25 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 10/25 pairs, cat. 3, with messenger
Fiber-optic
Indoor
• Zip-cord
• With tight buffer
• Multi loose tube
Indoor/outdoor
• With tight buffer
• Multi loose tube
Outdoor
• Single loose tube
• Multi loose tube, with messenger
• With tight buffer, with steel armored band
• Single loose tube, with steel armored band
• Multi loose tube, with steel armored band
• Multi loose tube, with steel armored wire
Telephone cable
• UTC solid, 10/25/50/100 pairs, cat. 2
• UTC stranded (patch), 4 wires, cat. 2
Hybrid cable
• Multiservice
• Video- and control
• Indoor
• Outdoor, armored
Coaxial cable
type RG-6
• COAX-RG6
• COAX-RG6-CU
• COAX-RG6-OUTDOOR/LSZH
• COAX-RG6-SW-OUTDOOR
type RG-8
• COAX-RG8
type RG-11
• COAX-RG11
type RG-58
• COAX-RG58
type RG-59
• COAX-RG59
• COAX-RG59-CU
• COAX-RG59-OUTDOOR/LSZH
• COAX-RG59-SW-OUTDOOR
type RG-213
• COAX-RG213
SAT703N, 75 Ohm
• COAX-SAT703N
Camera cable
• RG 59, 75 Ohm, 2 x 0.5 mm
• RG 59, 75 Ohm, 2 x 0.75 mm
Industrial cable
Industrial Ethernet
Shielded
• FTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid, outdoor
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 3 pairs
• RS-422/485, 4 pairs
In double PVC jacket, armored
• RS-422/485, 2 pairs, every pair is separately shielded
• RS-422/485, 3 pairs, every pair is separatly shielded
• RS-422/485, 4 pairs, every pair is separatly shielded
• RS-422/485, 8 pairs, every pair is separatly shielded
• RS-422/485, 2 pairs, common shield
ProfiBus
• SFTP, 1 pair, solid, PVC jacket
• SFTP, 1 pair, solid, polyethylene jacket
• SFTP, 1 pair, solid, polyurethane jacket
• SFTP, 1 pair, solid, PVC and polyethylene jackets
• SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
• FC-SFTP, 1 pair, solid, PVC jacket
• FC-SFTP, 1 pair, solid, polyethylene jacket
• FTP, 1 pair, stranded (patch), PVC jacket
• PA-STP, 1 pair, stranded (patch), PVC jacket
• SFTP, 1 pair, stranded (patch), polyurethane jacket
• SFTP, 1 pair, stranded (patch), FR-LSZH
• L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH
Installation Accessories
Tools
Racks and Cabinets
Power Distribution Units
Access Floors
Axelent Cable Trays
Wire Mesh Cable Trays
Production Shutdown
|
|
Industrial Ethernet cable, 2x2x24 AWG (multiwire conductors) SFTP, in double PVC jacket, for installation in rising mains (index CMR)
 |
1 - Jacket
2 - Shield - braid
3 - Shield - foil
4 - Inner jacket
5 - Stranded twisted pair
6 - Main load-bearing element
|
Description
The cable of category 5e for service cables consists of 2 twisted pairs covered with double PVC jacket braided with load-bearing elements. The PVC jacketed inner core is shielded with foil and copper braid and covered with PVC jacket. The cable is designed for application within the industrial networks like Industrial Ethernet and is suitable for installation in rising mains (index CMR).
The cable complies with ANSI/TIA/EIA-568-B.2 and ISO/IEC 11801; UL 1581 VW-1 and IEC 60332.1.
|
Materials
The conducting material is annealed soft electrolytic copper conductor, stranded
Core insulation: polyolefin
Shield: tinned copper wire braid, foil coating density 100%, braid coating density 65%
Jacket: PVC-compound, optimized for installation in rising mains
|
Technical characteristics
| Conductor (core) diameter |
7x0.203 mm (7 x 0.008", 24 AWG) |
| Insulated conductor diameter |
0.98 mm (0.04") |
| Inner jacket diameter |
5.7 mm (0.22") |
| Cable weight per 1000 ft |
21.6 kg (47.6 lbs) |
| Cable outer diameter |
7.4 mm (0.29") |
| Operation temperature |
-40°C – +70°C (-40°F – +158°F) |
| Cabling temperature |
-40°C – +60°C (-40°F – +140°F) |
| Bend radius |
20 outer diameters (padding), 10 outer diameters (operation) |
| Tension force |
80 N |
Electrical characteristics:
| Maximum direct current conductor resistance at 20°C (68°F) |
94 Ohm/km (151.28 Ohm/mile) |
| Min. insulating resistance |
5 GOhm*km (3106.85 MOhm*mile) |
| Max. Ohmic asymmetry |
2% |
| Capacitive asymmetry at the frequency of 1 kHz |
3.2 pF/m (0.98 pF/ft) |
| Mutual capacity at the frequency of 1 kHz |
46 pF/m (14.02 pF/ft) |
| Propagation velocity |
68% – monolithic insulation, 75% – cellular insulation |
| Max. operating voltage |
230 V |
| Dielectric breakdown strength |
700 V/1 min |
| Wave impedance at the frequency of 1-100 MHz |
100 ± 15 Ohm |
| Propagation delay at the frequency of 1 kHz |
570 ns/100 m (173.74 ns/100 ft) |
| Phase shift at the frequency of 1-100 MHz |
35 ns/100 m (10.67 ns/100 ft) |
Ordering:
| ISF2-C5e-P-I-CMR |
Industrial Ethernet cable, 2x2x24 AWG (multiwire conductors) SFTP, in double PVC jacket, for installation in rising mains (index CMR) |
| |
There is a Minimum Order Quantity applied to this product. Contact our Sales Department for more information |
|
|
| |
e-mail: info@hyperline.com Copyright © 2003-2012 HYPERLINE® Registered Trade-mark; used under license
|
TERMS AND CONDITIONS OF SALE |
 |
|
|