Catalog

Industrial Ethernet cable, 2x2x24 AWG (multiwire conductors) UTP, in double PVC jacket, for installation in rising mains (index CMR)

1 - Jacket
2 - Inner jacket
3 - Stranded twisted pair
4 - Main load-bearing element
Description
The unshielded cable of category 5e for service cables consists of 2 twisted pairs covered with double PVC jacket braided with load-bearing elements. The cable is designed for application within the industrial networks like Industrial Ethernet and is suitable for installation in rising mains (index CMR).
The cable complies with ANSI/TIA/EIA-568-B.2 and ISO/IEC 11801; UL 1581 VW-1 and IEC 60332.1.

Materials
The conducting material is annealed soft electrolytic copper wire, stranded
Core insulation: polyolefin
Jacket: PVC-compound, optimized for installation in rising mains

Technical characteristics
Conductor (core) diameter 7x0.203 mm (7 x 0.008", 24 AWG)
Insulated conductor diameter 0.97 mm (0.04")
Inner jacket diameter 4.6 mm (0.18")
Cable weight per 1000 ft 13 kg (28.8 lbs)
Cable outer diameter 5.9 mm (0.23")
Operation temperature -40°C – +70°C (-40°F – +158°F)
Cabling temperature -40°C – +60°C (-40°F – +140°F)
Bend radius 20 outer diameters (padding), 10 outer diameters (operation)
Tension force 50 N

Electrical characteristics:
Maximum direct current conductor resistance at 20°C (68°F) 94 Ohm/km (151.28 Ohm/mile)
Min. insulating resistance 5 GOhm*km (3106.85 MOhm*mile)
Max. Ohmic asymmetry 2%
Capacitive asymmetry at the frequency of 1 kHz 3.2 pF/m (0.98 pF/ft)
Mutual capacity at the frequency of 1 kHz 46 pF/m (14.02 pF/ft)
Propagation velocity 68% – monolithic insulation, 75% – cellular insulation
Max. operating voltage 230 V
Dielectric breakdown strength 700 V/1 min
Wave impedance at the frequency of 1-100 MHz 100 ± 15 Ohm
Propagation delay at the frequency of 1 kHz 570 ns/100 m (173.74 ns/100 ft)
Phase shift at the frequency of 1-100 MHz 35 ns/100 m (10.67 ns/100 ft)
Ordering:
IU2-C5e-P-I-CMR Industrial Ethernet cable, 2x2x24 AWG (multiwire conductors) UTP, in double PVC jacket, for installation in rising mains (index CMR)
  There is a Minimum Order Quantity applied to this product. Contact our Sales Department for more information