COMPONENTS OF STRUCTURED CABLING SYSTEMS

   


Patch Panels

Work Area Outlets

Keystone Jacks

Modular Plugs

Cross Connection

Fiber Optic

Cable Managers

Patch Cords

Cables

Twisted pair cable

Indoor, unshielded
UTP solid, 4 pairs, cat. 6, PVC
UTP patch, 4 pairs, cat. 6, PVC
UTP patch, 4 pairs, cat. 6, with spacer, PVC
UTP solid, 4 pairs, cat. 6, LSZH
UTP solid, 4 pairs, cat. 6 Plenum
UTP solid, 2 pairs, cat. 5, PVC
UTP solid, 2 pairs, cat. 5, LSZH
UTP solid, 4 pairs, cat. 5e, PVC
UTP solid, 4 pairs x 2, cat. 5e, PVC
UTP patch, 4 pairs, cat. 5e, PVC
UTP solid, 4 pairs, cat. 5e, LSZH
UTP solid, 4 pairs, cat. 5e, Plenum
UTP patch, 1 pair, cat. 5e, PVC
UTP solid 1 pair, cat. 5e, cross
UTP patch, 2 pairs, cat. 5e, PVC
UTP solid, 10/25/50/100 pairs, cat. 3, PVC
UTP solid, 25/50/100 pairs, cat. 5, PVC
UTP solid, 12/16/24/48/100 pairs, cat. 5, PVC
UTP solid, 8/10/12/16 pairs, cat. 5, PVC
UTP solid, 24 pairs, cat. 6, FR-PVC
UFTP solid, 24 pairs, cat. 6a, FR-LSZH
UTP solid, 25 pairs(4x6+1), cat. 5, PVC
Indoor, shielded
SSTP solid, 4 pairs, cat. 7a (10 GBE),
FR-LSZH

FFTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
SSTP solid, 4 pairs, cat. 7 (1200 MHz), LSZH
SSTP solid, 4 pairs, cat. 7 (1200 MHz), FR-PVC
SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-PVC
SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-LSZH
SSTP patch, 4 pairs, cat. 7 (600 MHz), LSZH
FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC-R
SFTP solid, 4 pairs, cat. 6a(10 GBE), FR-LSZH
SFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
UFTP solid, 4 pairs, cat. 6, FR-LSZH
USTP solid, 4 pairs, cat. 6a
SSTP solid, 4 pairs, cat. 6
SSTP patch, 4 pairs, cat. 6
STP solid, 4 pairs, cat. 6, PVC
STP patch, 4 pairs, cat. 6
FTP solid, 4 pairs, cat. 6, PVC
FTP solid, 4 pairs, cat. 5e
FTP solid, 4 pairs, cat. 5e LSZH
FTP patch, 4 pairs, cat. 5e
SFTP solid, 4 pairs, cat. 5e
SFTP patch, 4 pairs, cat. 5e
FTP solid, 2 pairs, cat. 5
FTP solid, 2 pairs, cat. 5, LSZH
FTP solid, 10/25/50/100 pairs, cat. 3
FTP solid, 25 pairs, cat. 5
FTP solid, 24/48/100 pairs, cat. 5e
SSTP solid, 24 pairs, cat. 7
FTP solid, 50 pairs, cat. 5
Outdoor, unshielded
USTP solid, 4 pairs, cat. 6a
UTP solid, 4 pairs, cat. 6
UTP solid, 4 pairs, cat. 5e
UTP solid, 4 pairs, cat. 5e, with messenger
UTP solid, 2 pairs, cat. 5
UTP solid, 2 pairs, cat. 5, with messenger
UTP solid, 25/50/100 pairs, cat. 5
UTP solid, 10/25/50/100 pairs, cat. 3
UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
UTP solid, 10/25/50/100 pairs, cat. 3, armored
UTP solid, 25 pairs(4x6+1), cat. 5, PE
Outdoor, shielded
SSTP solid, 4 pairs, cat. 7, 10GBE
SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
SSTP solid, 4 pairs, cat. 7
STP solid, 4 pairs, cat. 6, FR-LSZH
STP solid, 4 pairs, cat. 6, FR-PVC
STP solid, 4 pairs, cat. 6
FTP solid, 4 pairs, cat. 5e
FTP solid, 4 pairs, cat. 5e, with messenger
FTP solid, 25 pairs, cat. 5
FTP solid, 2 pairs, cat. 5
FTP solid, 2 pairs, cat. 5, with messenger
FTP solid, 10/25/50/100 pairs, cat. 3
FTP solid, 10/25 pairs, cat. 3, with messenger


Fiber-optic

Indoor
Zip-cord
With tight buffer
Multi loose tube
Indoor/outdoor
With tight buffer
Multi loose tube
Outdoor
Single loose tube
Multi loose tube, with messenger
With tight buffer, with steel armored band
Single loose tube, with steel armored band
Multi loose tube, with steel armored band
Multi loose tube, with steel armored wire

Telephone cable

UTC solid, 10/25/50/100 pairs, cat. 2
UTC stranded (patch), 4 wires, cat. 2

Hybrid cable

Multiservice
Video- and control
Indoor
Outdoor, armored

Coaxial cable

type RG-6
COAX-RG6
COAX-RG6-CU
COAX-RG6-OUTDOOR/LSZH
COAX-RG6-SW-OUTDOOR
type RG-8
COAX-RG8
type RG-11
COAX-RG11
type RG-58
COAX-RG58
type RG-59
COAX-RG59
COAX-RG59-CU
COAX-RG59-OUTDOOR/LSZH
COAX-RG59-SW-OUTDOOR
type RG-213
COAX-RG213
SAT703N, 75 Ohm
COAX-SAT703N
Camera cable
RG 59, 75 Ohm, 2 x 0.5 mm
RG 59, 75 Ohm, 2 x 0.75 mm

Industrial cable

Industrial Ethernet
Shielded
FTP, 4 pairs, cat.5e, solid
SFTP, 2 pairs, cat.5e, solid
SFTP, 4 pairs, cat.5e, solid
SFTP, 2 pairs, cat.5e, stranded (patch)
SFTP, 4 pairs, cat.5e, stranded (patch)
SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
SFTP, 2 pairs, cat.5e, solid
SFTP, 4 pairs, cat.5e, solid
SFTP, 2 pairs, cat.5e, stranded (patch)
SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
UTP, 2 pairs, cat.5e, solid
UTP, 4 pairs, cat.5e, solid
UTP, 4 pairs, cat.5e, solid, outdoor
UTP, 2 pairs, cat.5e, stranded (patch)
UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
UTP, 2 pairs, cat.5e, solid
UTP, 4 pairs, cat.5e, solid
UTP, 2 pairs, cat.5e, stranded (patch)
UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
RS-485, 1 pair
RS-422/485, 2 pairs
RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
RS-485, 1 pair
RS-422/485, 2 pairs
RS-422/485, 3 pairs
RS-422/485, 4 pairs
In double PVC jacket, armored
RS-422/485, 2 pairs, every pair is separately shielded
RS-422/485, 3 pairs, every pair is separatly shielded
RS-422/485, 4 pairs, every pair is separatly shielded
RS-422/485, 8 pairs, every pair is separatly shielded
RS-422/485, 2 pairs, common shield
ProfiBus
SFTP, 1 pair, solid, PVC jacket
SFTP, 1 pair, solid, polyethylene jacket
SFTP, 1 pair, solid, polyurethane jacket
SFTP, 1 pair, solid, PVC and polyethylene jackets
SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
FC-SFTP, 1 pair, solid, PVC jacket
FC-SFTP, 1 pair, solid, polyethylene jacket
FTP, 1 pair, stranded (patch), PVC jacket
PA-STP, 1 pair, stranded (patch), PVC jacket
SFTP, 1 pair, stranded (patch), polyurethane jacket
SFTP, 1 pair, stranded (patch), FR-LSZH
L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH

Installation Accessories

Tools

Racks and Cabinets

Power Distribution Units

Access Floors

Axelent Cable Trays

Wire Mesh Cable Trays

Production Shutdown




Catalog

Coaxial cable RG-6-U, Outdoor, with a self-supporting wire, PE

Coaxial cable RG-6-U, outdoor, with a self-supporting wire, PE

Specifications:
Fire protection - CM
The cable meets UL 1581 fire safety standard

Description:
The coaxial cable with wave impedance of 75 Ohm and a self-supporting wire; designed for application in DBS, SAT, CATV. Can be used indoor and outdoor; suitable for air-laying and direct burial application.

Materials:
Conductor: copper covered steel (CCS)
Insulation: polyethylene foam (PE foam)
Shield: polyether foil with aluminum alloy on both sides and aluminum wire braid
The cable jacket: polyethylene
Self-supporting wire: galvanized steel

Technical characteristics:
Conductor diameter: 1.002 mm (0.0394") (18 AWG)
Insulation Diameter: 4.57 mm (0.18")
Centricity: 85%
Outer cable diameter: 6.86 mm (0.27")
Jacket color: black
Shield: polyether foil - 100% covering density; braid - 60% coverage
Max. pulling tension: 470.6 N
Min. bending radius: installation - 22.85 mm (0.899"), repeated - 68.6 mm (2.707")
Self-supporting wire (messenger): 7 x 0.40 mm (0.0157"), outside diameter - 1.25 mm (0.049")
Storage temperature: -20°C - +60°C (-4°F - +140°F)
Operating temperature: -40°C - +60°C (-40°F - +140°F)
Weight per 1000 ft (304.8 m): 23.52 lbs (10.67 kg)

Electrical characteristics
Frenqency, MHz Attenuation (dB/100M) at 20°C (-68°F)
5.0 2.80
50.0 5.50
100.0 6.90
200.0 9.50
400.0 15.0
800.0 19.5
1000.0 21.5
2150.0 32.5
2200.0 33.0
3000.0 39.0

Characteristic impedance 75 ± 3 Ohm
Capacitance 51 ± 1 pF/m
Velocity of propagation 84%
DCR: Inner conductor < 102 ohm/km
DCR: Outer conductor < 21 ohm/km
Spark test 2500 V
Dielectric strength 1500 V
Return loss at 5 - 1000 MHz 23 dB
Return loss at 1000 - 2000 MHz 20 dB
Return loss at 2000 - 3000 MHz 18 dB
Insulation resistance > 100 000 ÌOhm
Screening factor at 30 - 1000 MHz > 80 dB

Ordering:
COAX-RG6-SW-OUTDOOR Coaxial cable RG6-SW, outdoor, self-supporting wire, PE

 
e-mail: info@hyperline.com
Copyright © 2003-2012 HYPERLINE® Registered Trade-mark; used under license

TERMS AND CONDITIONS OF SALE