Patch panels
Work area outlets
Keystone Jacks
Modular plugs
Cross Connection
Fiber Optic
Cable managers
Patch cords
Cables
Twisted pair cable
Indoor, unshielded
• UTP solid, 4 pairs, cat. 6
• UTP stranded (patch), 4 pairs, cat. 6
• UTP stranded (patch), 4 pairs, cat. 6, with spacer
• UTP solid, 4 pairs, cat. 6 LSZH
• UTP solid, 4 pairs, cat. 6 Plenum
• UTP solid 1 pair, cat. 5e, cross
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e LSZH
• UTP solid, 4 pairs, cat. 5e Plenum
• UTP stranded (patch), 1 pair, cat. 5e
• UTP stranded (patch), 2 pairs, cat. 5e
• UTP stranded (patch), 4 pairs, cat. 5e
• UTP solid, 2 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 12/16/24/48/100 pairs, cat. 5
• UTP solid, 8/10/12/16 pairs, cat. 5
• UTP solid, 24 pairs, cat. 6
• UFTP solid, 24 pairs, cat. 6a
Indoor, shielded
• SSTP solid, 4 pairs, cat. 8
• SSTP solid, 4 pairs, cat. 7a
• FFTP solid, 4 pairs, cat. 7, LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), FRPVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FRPVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
• SSTP stranded (patch), 4 pairs, cat. 7
• USTP solid, 4 pairs, cat. 6a
• SSTP solid, 4 pairs, cat. 6
• SSTP stranded (patch), 4 pairs, cat. 6
• STP solid, 4 pairs, cat. 6
• STP stranded (patch), 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e LSZH
• FTP solid, 4 pairs, cat. 5e Plenum
• FTP solid, 24/48/100 pairs, cat. 5e
• SFTP solid, 4 pairs, cat. 5e
• FTP stranded (patch), 4 pairs, cat. 5e
• SFTP stranded (patch), 4 pairs, cat. 5e
• FTP solid, 25 pairs, cat. 5
• FTP solid, 10/25/50/100 pairs, cat. 3
• SSTP solid, 24 pairs, cat. 7
Outdoor, unshielded
• USTP solid, 4 pairs, cat. 6a
• UTP solid, 4 pairs, cat. 6
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e, with messenger
• UTP solid, 2 pairs, cat. 5
• UTP solid, 2 pairs, cat. 5, with messenger
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• UTP solid, 10/25/50/100 pairs, cat. 3, armored
Outdoor, shielded
• SSTP solid, 4 pairs, cat. 7, 10GBE
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
• SSTP solid, 4 pairs, cat. 7
• STP solid, 4 pairs, cat. 6, FR-LSZH
• STP solid, 4 pairs, cat. 6, FR-PVC
• STP solid, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e, with messenger
• FTP solid, 25 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3, armored
Fiber-optic
Indoor
• Zip-cord
• With tight buffer
• Multi loose tube
Indoor/outdoor
• With tight buffer
• Multi loose tube
Outdoor
• Single loose tube
• Multi loose tube, with messenger
• With tight buffer, with steel armored band
• Single loose tube, with steel armored band
• Multi loose tube, with steel armored band
• Multi loose tube, with steel armored wire
Telephone cable
• UTC solid, 10/25/50/100 pairs, cat. 2
• UTC stranded (patch), 4 wires, cat. 2
Hybrid cable
• Multiservice
• Video- and control
• Indoor
• Outdoor, armored
Coaxial cable
• type RG-6
• type RG-8
• type RG-11
• type RG-58
• type RG-59
• type RG-213
Camera cable
• RG 59, 75 Ohm, with two conductors 0.5 mm
• RG 59, 75 Ohm, with two conductors 0.75 mm
Industrial cable
Industrial Ethernet
Shielded
• FTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid, outdoor
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 3 pairs
• RS-422/485, 4 pairs
In double PVC jacket, armored
• RS-422/485, 2 pairs, every pair is separately shielded
• RS-422/485, 3 pairs, every pair is separatly shielded
• RS-422/485, 4 pairs, every pair is separatly shielded
• RS-422/485, 8 pairs, every pair is separatly shielded
• RS-422/485, 2 pairs, common shield
ProfiBus
• SFTP, 1 pair, solid, PVC jacket
• SFTP, 1 pair, solid, polyethylene jacket
• SFTP, 1 pair, solid, polyurethane jacket
• SFTP, 1 pair, solid, PVC and polyethylene jackets
• SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
• FC-SFTP, 1 pair, solid, PVC jacket
• FC-SFTP, 1 pair, solid, polyethylene jacket
• FTP, 1 pair, stranded (patch), PVC jacket
• PA-STP, 1 pair, stranded (patch), PVC jacket
• SFTP, 1 pair, stranded (patch), polyurethane jacket
• SFTP, 1 pair, stranded (patch), FR-LSZH
• L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH
Installation accessories
Tools
Racks and cabinets
Power Distribution Units
Wiring Ducts and Trunking
Access floors
Wire Mesh Cable Trays and CombiRack System
Production shutdown
|
|
Unshielded Twisted Pair Cable (UTP), 10/25/50/100 pairs, Solid, Indoor (Category 3)
Specifications:
Meets EIA/TIA 568-B for category 3 requirements
Fire protection – IEC60332-1 (CM)
The cable meets IEC 60332-1 fire safety standard
|
Description:
Unshielded Copper cable, 10/25/50/100 pairs, category 3, solid.
Cable is used for indoor installation
|
Materials:
Conductive material: soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC
|
Electrical characteristics:
| Max DC Resistance at 20°C (68°F) |
9.38 Ohm/100 m (2.9 Ohm/100 ft) |
| Max Resistance Unbalance |
3% |
Max Capacitance unbalance – pair-to-ground at 1kHz |
330 pF/100 m (101 pF/100 ft) |
| Characteristic Impedance at 1-16 MHz |
85-115 Ohm |
Min worst pair Structural Return Loss (SRL)
Up to 10 MHz
At 16 MHz |
12 dB 10 dB |
Max attenuation at 20°C (68°F) and
At 772 kHz
At 1 MHz
At 4 MHz
At 8 MHz
At 10 MHz
At 16 MHz
|
2.2 dB/100 m (0.67 dB/100 ft) 2.6 dB/100 m (0.79 dB/100 ft) 5.6 dB/100 m (1.70 dB/100 ft) 8.5 dB/100 m (2.59 dB/100 ft) 9.7 dB/100 m (2.96 dB/100 ft) 13.1 dB/100 m (3.99 dB/100 ft) |
Min worst pair to pair NEXT loss at 772 kHz
At 1 MHz
At 4 MHz
At 8 MHz
At 10 MHz
At 16 MHz |
43 dB 41 dB 32 dB 27 dB 26 dB 23 dB |
Min Relative Velocity of Propagation at 10 MHz |
0,585 |
10 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
|
Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 7.5 mm (0.29")
Jacket thickness: 1.0 mm (0.039")
Maximum strand pitch: 100 mm (3.93")
Minimum bend radius: 6 outer cable diameters
Conductor elongation: 14% minimum
Operating temperature: -10°C – +50°C (+14°F – +122°F)
Weight per 1000 ft (304.8 m): 19.5 kg (43 lbs)
Standard package: 1000 m (3280 ft)
|
25 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
|
Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 11 mm (0.43")
Jacket thickness: 1.0 mm (0.039")
Maximum strand pitch: 100 mm (3.93")
Minimum bend radius: 6 outer cable diameters
Conductor elongation: 14% minimum
Operating temperature: -10°C – +50°C (+14°F – +122°F)
Weight per 1000 ft (304.8 m): 46.6 kg (102.8 lbs)
Standard package: 1000 m (3280 ft)
|
50 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
|
Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 15 mm (0.59")
Jacket thickness: 1.0 mm (0.039")
Maximum strand pitch: 150 mm (5.9")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Operating temperature: -10°C – +50°C (+14°F – +122°F)
Weight per 1000 ft (304.8 m): 89.3 kg (196.9 lbs)
Standard package: 500 m (1640 ft)
|
100 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
|
Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 200 mm (0.78")
Jacket thickness: 1.0 mm (0.039")
Maximum strand pitch: 150 mm (5.9")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Operating temperature: -10°C – +50°C (+14°F – +122°F)
Weight per 1000 ft (304.8 m): 169.2 kg (372.9 lbs)
Standard package: 500 m (1640 ft)
|
Ordering:
| UTPXX-C3-SOLID-INDOOR |
Unshielded Twisted Pair Cable UTP, 10/25/50/100 pairs, solid, indoor, category 3 |
| UTP100-C3-SOLID-INDOOR-HFFR |
Unshielded Twisted Pair Cable UTP, 100 pairs, solid, indoor, category 3, halogenfree, fire resistant jacket
|
XX – quantity of pairs: 10, 25, 50, 100 pairs
|
|