Patch Panels
Work Area Outlets
Keystone Jacks
Modular Plugs
Cross Connection
Fiber Optic
Cable Managers
Patch Cords
Cables
Twisted pair cable
Indoor, unshielded
• UTP solid, 4 pairs, cat. 6, PVC
• UTP patch, 4 pairs, cat. 6, PVC
• UTP patch, 4 pairs, cat. 6, with spacer, PVC
• UTP solid, 4 pairs, cat. 6, LSZH
• UTP solid, 4 pairs, cat. 6 Plenum
• UTP solid, 2 pairs, cat. 5, PVC
• UTP solid, 2 pairs, cat. 5, LSZH
• UTP solid, 4 pairs, cat. 5e, PVC
• UTP solid, 4 pairs x 2, cat. 5e, PVC
• UTP patch, 4 pairs, cat. 5e, PVC
• UTP solid, 4 pairs, cat. 5e, LSZH
• UTP solid, 4 pairs, cat. 5e, Plenum
• UTP patch, 1 pair, cat. 5e, PVC
• UTP solid 1 pair, cat. 5e, cross
• UTP patch, 2 pairs, cat. 5e, PVC
• UTP solid, 10/25/50/100 pairs, cat. 3, PVC
• UTP solid, 25/50/100 pairs, cat. 5, PVC
• UTP solid, 12/16/24/48/100 pairs, cat. 5, PVC
• UTP solid, 8/10/12/16 pairs, cat. 5, PVC
• UTP solid, 24 pairs, cat. 6, FR-PVC
• UFTP solid, 24 pairs, cat. 6a, FR-LSZH
• UTP solid, 25 pairs(4x6+1), cat. 5, PVC
Indoor, shielded
• SSTP solid, 4 pairs, cat. 7a (10 GBE), FR-LSZH
• FFTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), FR-PVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-PVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FR-LSZH
• SSTP patch, 4 pairs, cat. 7 (600 MHz), LSZH
• FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
• FFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC-R
• SFTP solid, 4 pairs, cat. 6a(10 GBE), FR-LSZH
• SFTP solid, 4 pairs, cat. 6a (10 GBE), FR-PVC
• USTP solid, 4 pairs, cat. 6a
• SSTP solid, 4 pairs, cat. 6
• SSTP patch, 4 pairs, cat. 6
• STP solid, 4 pairs, cat. 6, PVC
• STP patch, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 6, PVC
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e LSZH
• FTP patch, 4 pairs, cat. 5e
• SFTP solid, 4 pairs, cat. 5e
• SFTP patch, 4 pairs, cat. 5e
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, LSZH
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 25 pairs, cat. 5
• FTP solid, 24/48/100 pairs, cat. 5e
• SSTP solid, 24 pairs, cat. 7
• FTP solid, 50 pairs, cat. 5
Outdoor, unshielded
• USTP solid, 4 pairs, cat. 6a
• UTP solid, 4 pairs, cat. 6
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e, with messenger
• UTP solid, 2 pairs, cat. 5
• UTP solid, 2 pairs, cat. 5, with messenger
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• UTP solid, 10/25/50/100 pairs, cat. 3, armored
• UTP solid, 25 pairs(4x6+1), cat. 5, PE
Outdoor, shielded
• SSTP solid, 4 pairs, cat. 7, 10GBE
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
• SSTP solid, 4 pairs, cat. 7
• STP solid, 4 pairs, cat. 6, FR-LSZH
• STP solid, 4 pairs, cat. 6, FR-PVC
• STP solid, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e, with messenger
• FTP solid, 25 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3, armored
Fiber-optic
Indoor
• Zip-cord
• With tight buffer
• Multi loose tube
Indoor/outdoor
• With tight buffer
• Multi loose tube
Outdoor
• Single loose tube
• Multi loose tube, with messenger
• With tight buffer, with steel armored band
• Single loose tube, with steel armored band
• Multi loose tube, with steel armored band
• Multi loose tube, with steel armored wire
Telephone cable
• UTC solid, 10/25/50/100 pairs, cat. 2
• UTC stranded (patch), 4 wires, cat. 2
Hybrid cable
• Multiservice
• Video- and control
• Indoor
• Outdoor, armored
Coaxial cable
type RG-6
• COAX-RG6
• COAX-RG6-CU
• COAX-RG6-OUTDOOR/LSZH
• COAX-RG6-SW-OUTDOOR
type RG-8
• COAX-RG8
type RG-11
• COAX-RG11
type RG-58
• COAX-RG58
type RG-59
• COAX-RG59
• COAX-RG59-CU
• COAX-RG59-OUTDOOR/LSZH
• COAX-RG59-SW-OUTDOOR
type RG-213
• COAX-RG213
Camera cable
• RG 59, 75 Ohm, 2 x 0.5 mm
• RG 59, 75 Ohm, 2 x 0.75 mm
Industrial cable
Industrial Ethernet
Shielded
• FTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid, outdoor
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 3 pairs
• RS-422/485, 4 pairs
In double PVC jacket, armored
• RS-422/485, 2 pairs, every pair is separately shielded
• RS-422/485, 3 pairs, every pair is separatly shielded
• RS-422/485, 4 pairs, every pair is separatly shielded
• RS-422/485, 8 pairs, every pair is separatly shielded
• RS-422/485, 2 pairs, common shield
ProfiBus
• SFTP, 1 pair, solid, PVC jacket
• SFTP, 1 pair, solid, polyethylene jacket
• SFTP, 1 pair, solid, polyurethane jacket
• SFTP, 1 pair, solid, PVC and polyethylene jackets
• SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
• FC-SFTP, 1 pair, solid, PVC jacket
• FC-SFTP, 1 pair, solid, polyethylene jacket
• FTP, 1 pair, stranded (patch), PVC jacket
• PA-STP, 1 pair, stranded (patch), PVC jacket
• SFTP, 1 pair, stranded (patch), polyurethane jacket
• SFTP, 1 pair, stranded (patch), FR-LSZH
• L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH
Installation Accessories
Tools
Racks and Cabinets
Power Distribution Units
Wiring Ducts and Trunking
Access Floors
Wire Mesh Cable Trays and CombiRack System
Production Shutdown
|
|
Unshielded Twisted Pair (UTP), 25/50/100 pairs, Solid, Outdoor, Category 5
Specifications:
Meets EIA/TIA 568-A requirements
Fire protection – CMX
The cable meets UL 1581 VW-1 fire safety standard
|
Description:
Unshielded Copper cable, 25/50/100 pairs, category 5, solid
Cable is used for outdoor installation
|
Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: UV resistant black PE
|
Electrical characteristics:
| Frequency, MHz |
Max Attenuation, dB/100 m (dB/100 ft) |
PS NEXT Loss, dB |
Min PS-ACR, dB/100 m (dB/100 ft) |
| 0.772 | 1.8 (0.55) | 64 | 62.2 (19.0) |
| 1.0 | 2.0 (0.6) | 62 | 60.0 (18.3) |
| 4.0 | 4.1 (1.3) | 53 | 48.9 (14.9) |
| 8.0 | 5.80 (1.8) | 48 | 42.2 (12.9) |
| 10.0 | 6.5 (2.0) | 47 | 40.5 (12.3) |
| 16.0 | 8.2 (2.5) | 44 | 35.8 (10.9) |
| 20.0 | 9.3 (2.8) | 42 | 32.8 (10.0) |
| 25.0 | 10.4 (3.2) | 41 | 30.6 (9.3) |
| 31.25 | 11.7 (3.6) | 39 | 28.3 (8.6) |
| 62.5 | 17.0 (5.2) | 35 | 18.0 (5.5) |
| 100.0 | 22.0 (6.7) | 32 | 10.0 (3.0) |
| Max DC Resistance at 20°C |
93.8 Ohm/km (151.3 Ohm/mile) |
| Max Resistance Unbalance |
5% |
| Characteristic Impedance at 1-100 MHz |
100 ± 15 Ohm |
| Capacitance at 1 kHz |
50 ± 4 pF/m (15.3 ± 1 pF/ft) |
| Max Capacitance unbalance at 1 kHz |
3300 pF/km (5322.6 pF/mile) |
| Longitudinal Conversion Loss at 64 kHz |
43 dB |
| Max. Voltage rating |
300 V |
| Dielectric Strength of Insulation |
1000 V RMS |
Max. Propagation Delay at 1 MHz at 10 MHz at 100 MHz |
5.7 ns/m (1.74 ns/ft) 5.4 ns/m (1.64 ns/ft) 5.3 ns/m (1.61 ns/ft) |
| Propagation Delay Skew at 1-100 MHz |
35 ns/100 m (10.67 ns/100 ft) |
| Insulation Resistance at 500 V |
5 GOhm/km (8.05 GOhm/mile) |
| Nominal Velocity of Propagation |
68% |
25 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Solid twisted pair
5 – Main load-bearing element
|
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.92 mm (0.036")
Outer cable diameter: 12.4 mm (0.48")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Installation temperature: -10°C to +40°C (+14°F to +104°F)
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft: 51.8 kg (114.2 lbs)
Standard package: 1000 m (3280 ft)
|
50 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Solid twisted pair
5 – Main load-bearing element
|
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
The outer cable diameter (size): 12.6 x 22.8 mm (0.49" x 0.89")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Installation temperature: -10°C to +40°C (+14°F to +104°F)
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft: 103.6 kg (228.5 lbs)
Standard package: 500 m (1640 ft)
|
100 pairs
 |
1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
6 – Marking tape
7 – Load-bearing elements
|
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
The outer cable diameter: 25.6 mm (1")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Installation temperature: -10°C to +40°C (+14°F to +104°F)
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft: 174 kg (383.7 lbs)
Standard package: 500 m (1640 ft)
|
Ordering:
| UTPXX-C5-SOLID-OUTDOOR |
Unshielded twisted pair (UTP), 25/50/100 pairs, solid, outdoor, category 5 |
XX – quatity of pairs: 25, 50, 100 pairs
|
|