Catalog

Twisted Pair Cable (UTP), 4 pairs, Category 6, Patch, with Spacer, PVC

Twisted pair cable UTP, category 6, 4 pares, stranded (patch)
Twisted pair cable UTP, category 6, 4 pairs, stranded (patch), with Spacer 1 – Jacket
2 – Stranded twisted pair
3 – Spacer



Specifications:
Meets ANSI/EIA/TIA 568-B.2-1 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard

Description:
Unshielded Copper cable, 4 pairs, category 6, stranded (patch)
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE, film-porous-film structure
The cable jacket: PVC

Technical characteristics:
Conductor diameter: 7 x 0.2 mm ± 0.01 mm (7" x 0.008" ± 0.004") (24 AWG)
Insulated conductor diameter: 0.04" ± 0.08" (1.03 ± 0.2 mm)
Outer cable diameter: 5.3 ± 0.2 mm (0.2" ± 0.008")
Jacket thickness: 0.4 mm (0.015")
Minimum bend radius: 4 outer cable diameters
Operating temperature: -5°C – +60°C (+23°F – +140°F)
Weight per 1000 ft (304.8 m): 13.7 kg (30.2 lbs)
Standard package: 305 m (1000 ft)

Electrical characteristics:
Frequency, MHz RL Attenuation, dB NEXT, dB PSNEXT, dB ELFEXT, dB PSELFEXT, dB
1.0 20.0 2.4 74.3 72.3 67.8 64.8
4.0 23.0 4.5 65.3 63.3 55.8 52.8
8.0 24.5 6.4 60.8 58.8 49.7 46.7
10.0 25.0 7.1 59.3 57.3 47.8 44.8
16.0 25.0 9.1 56.2 54.2 43.7 40.7
20.0 25.0 10.2 54.8 52.8 41.8 38.8
25.0 24.2 11.4 53.3 51.3 39.8 36.8
31.25 23.3 12.8 51.9 49.9 37.9 34.9
62.5 20.7 18.5 47.4 45.4 31.9 28.9
100.0 19.0 23.8 44.3 42.3 27.8 24.8
200.0 16.4 34.8 39.8 37.8 21.8 18.8
250.0 15.6 39.4 38.3 36.3 19.8 16.8


Conductor resistance at 20°C (68°F) 9.38 Ohm/100 m (2.9 Ohm/100 ft)
DC Resistance Unbalance 5%
Pair-to-Ground Capacitance Unbalance 330 pF/100 m (101 pF/100 ft)
Impedance 0.772-100 MHz 85-115 Ohm
Mutual Capacitance 5.6 nF/m (1.7 nF/ft)
Spark Test 2.5 kV


Ordering:
UTP4-C6-PATCH-GY Twisted Pair Cable (UTP), 4 pairs, Category 6, Patch, with Spacer, PVC, grey