Twisted Pair Cable (UTP), 4 pairs, Category 6, Solid, PVC
 |
1 – Jacket
2 – Solid twisted pair
3 – Spacer
|
Specifications:
Meet ANSI/EIA/TIA 568-B.2-1 requirements
Fire protection – IEC60332-1 (CM)
The cable meets UL 1581 VW-1 fire safety standard
|
Description:
Unshielded copper cable, 4 pairs, category 6, solid
Cable is used for indoor installation
|
Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC
|
Technical characteristics:
Conductor diameter: 0.54 ± 0.01 mm (24 AWG)
Insulated conductor diameter: 0.99 ± 0.2 mm (0.038" ± 0.008")
Outer cable diameter: 6.2 ± 0.2 mm (0.24" ± 0.008")
Jacket thickness: 0.4 mm (0.015")
Pulling strength: 130 N
Minimum bend radius: 4 outer cable diameters
Operating temperature: -20°C to +75°C (-4°F to +167°F)
Weight per 1000 ft: 12.9 kg (28.4 lbs)
Standard package: 305 m (1000 ft)
|
Electrical characteristics:
| Frequency, MHz |
RL |
Attenuation, dB |
NEXT, dB |
PSNEXT, dB |
ELFEXT, dB |
PSELFEXT, dB |
| 1.0 |
20.0 |
2.0 |
74.3 |
72.3 |
67.8 |
64.8 |
| 4.0 |
20.3 |
3.8 |
65.3 |
63.3 |
55.8 |
52.8 |
| 8.0 |
24.5 |
5.3 |
60.8 |
58.8 |
49.7 |
46.7 |
| 10.0 |
25.0 |
6.0 |
59.3 |
57.3 |
47.8 |
44.8 |
| 16.0 |
25.0 |
7.6 |
56.3 |
54.3 |
43.7 |
40.7 |
| 20.0 |
25.0 |
8.5 |
54.8 |
52.8 |
41.8 |
38.8 |
| 25.0 |
24.3 |
9.5 |
53.3 |
51.3 |
39.8 |
36.8 |
| 31.25 |
23.6 |
10.7 |
51.9 |
49.9 |
37.9 |
34.9 |
| 62.5 |
21.5 |
15.4 |
47.4 |
45.4 |
31.9 |
28.9 |
| 100.0 |
20.1 |
19.8 |
44.3 |
42.3 |
27.8 |
24.8 |
| 200.0 |
18.0 |
29.0 |
39.8 |
37.8 |
21.8 |
18.8 |
| 250.0 |
17.3 |
32.8 |
38.3 |
36.3 |
19.8 |
16.8 |
| Conductor resistance at 20°C (68°F) |
9.38 Ohm/100 m (2.9 Ohm/100 ft) |
| DC Resistance Unbalance |
5% |
| Pair-to-Ground Capacitance Unbalance |
330 pF/100 m (101 pF/100 ft) |
| Impedance 0.772-100 MHz |
85-115 Ohm |
| Mutual Capacitance |
5.6 nF/m (1.7 nF/ft) |
| Spark Test |
2.5 kV |
Ordering:
| UTP4-C6-SOLID-GY |
Twisted Pair cable UTP, category 6, 4 pairs, solid |
|
|