Patch panels
Work area outlets
Keystone Jacks
Modular plugs
Cross Connection
Fiber Optic
Cable managers
Patch cords
Cables
Twisted pair cable
Indoor, unshielded
• UTP solid, 4 pairs, cat. 6
• UTP stranded (patch), 4 pairs, cat. 6
• UTP stranded (patch), 4 pairs, cat. 6, with spacer
• UTP solid, 4 pairs, cat. 6 LSZH
• UTP solid, 4 pairs, cat. 6 Plenum
• UTP solid 1 pair, cat. 5e, cross
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e LSZH
• UTP solid, 4 pairs, cat. 5e Plenum
• UTP stranded (patch), 1 pair, cat. 5e
• UTP stranded (patch), 2 pairs, cat. 5e
• UTP stranded (patch), 4 pairs, cat. 5e
• UTP solid, 2 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 12/16/24/48/100 pairs, cat. 5
• UTP solid, 8/10/12/16 pairs, cat. 5
• UTP solid, 24 pairs, cat. 6
• UFTP solid, 24 pairs, cat. 6a
Indoor, shielded
• SSTP solid, 4 pairs, cat. 8
• SSTP solid, 4 pairs, cat. 7a
• FFTP solid, 4 pairs, cat. 7, LSZH
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), FRPVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), FRPVC
• SSTP solid, 4 pairs, cat. 7 (1000 MHz), LSZH
• SSTP stranded (patch), 4 pairs, cat. 7
• USTP solid, 4 pairs, cat. 6a
• SSTP solid, 4 pairs, cat. 6
• SSTP stranded (patch), 4 pairs, cat. 6
• STP solid, 4 pairs, cat. 6
• STP stranded (patch), 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e LSZH
• FTP solid, 4 pairs, cat. 5e Plenum
• FTP solid, 24/48/100 pairs, cat. 5e
• SFTP solid, 4 pairs, cat. 5e
• FTP stranded (patch), 4 pairs, cat. 5e
• SFTP stranded (patch), 4 pairs, cat. 5e
• FTP solid, 25 pairs, cat. 5
• FTP solid, 10/25/50/100 pairs, cat. 3
• SSTP solid, 24 pairs, cat. 7
Outdoor, unshielded
• USTP solid, 4 pairs, cat. 6a
• UTP solid, 4 pairs, cat. 6
• UTP solid, 4 pairs, cat. 5e
• UTP solid, 4 pairs, cat. 5e, with messenger
• UTP solid, 2 pairs, cat. 5
• UTP solid, 2 pairs, cat. 5, with messenger
• UTP solid, 25/50/100 pairs, cat. 5
• UTP solid, 10/25/50/100 pairs, cat. 3
• UTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• UTP solid, 10/25/50/100 pairs, cat. 3, armored
Outdoor, shielded
• SSTP solid, 4 pairs, cat. 7, 10GBE
• SSTP solid, 4 pairs, cat. 7 (1200 MHz), PE
• SSTP solid, 4 pairs, cat. 7
• STP solid, 4 pairs, cat. 6, FR-LSZH
• STP solid, 4 pairs, cat. 6, FR-PVC
• STP solid, 4 pairs, cat. 6
• FTP solid, 4 pairs, cat. 5e
• FTP solid, 4 pairs, cat. 5e, with messenger
• FTP solid, 25 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5
• FTP solid, 2 pairs, cat. 5, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3
• FTP solid, 10/25/50/100 pairs, cat. 3, with messenger
• FTP solid, 10/25/50/100 pairs, cat. 3, armored
Fiber-optic
Indoor
• Zip-cord
• With tight buffer
• Multi loose tube
Indoor/outdoor
• With tight buffer
• Multi loose tube
Outdoor
• Single loose tube
• Multi loose tube, with messenger
• With tight buffer, with steel armored band
• Single loose tube, with steel armored band
• Multi loose tube, with steel armored band
• Multi loose tube, with steel armored wire
Telephone cable
• UTC solid, 10/25/50/100 pairs, cat. 2
• UTC stranded (patch), 4 wires, cat. 2
Hybrid cable
• Multiservice
• Video- and control
• Indoor
• Outdoor, armored
Coaxial cable
• type RG-6
• type RG-8
• type RG-11
• type RG-58
• type RG-59
• type RG-213
Camera cable
• RG 59, 75 Ohm, with two conductors 0.5 mm
• RG 59, 75 Ohm, with two conductors 0.75 mm
Industrial cable
Industrial Ethernet
Shielded
• FTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch), outdoor
Shielded, for installation in rising mains
• SFTP, 2 pairs, cat.5e, solid
• SFTP, 4 pairs, cat.5e, solid
• SFTP, 2 pairs, cat.5e, stranded (patch)
• SFTP, 4 pairs, cat.5e, stranded (patch)
Unshielded
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid, outdoor
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Unshielded, for installation in rising mains
• UTP, 2 pairs, cat.5e, solid
• UTP, 4 pairs, cat.5e, solid
• UTP, 2 pairs, cat.5e, stranded (patch)
• UTP, 4 pairs, cat.5e, stranded (patch)
Cable of interface
Temperature range (-55°C to +70°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 4 pairs
Temperature range (-45°C to +80°C)
• RS-485, 1 pair
• RS-422/485, 2 pairs
• RS-422/485, 3 pairs
• RS-422/485, 4 pairs
In double PVC jacket, armored
• RS-422/485, 2 pairs, every pair is separately shielded
• RS-422/485, 3 pairs, every pair is separatly shielded
• RS-422/485, 4 pairs, every pair is separatly shielded
• RS-422/485, 8 pairs, every pair is separatly shielded
• RS-422/485, 2 pairs, common shield
ProfiBus
• SFTP, 1 pair, solid, PVC jacket
• SFTP, 1 pair, solid, polyethylene jacket
• SFTP, 1 pair, solid, polyurethane jacket
• SFTP, 1 pair, solid, PVC and polyethylene jackets
• SFTP, 1 pair, solid, PVC and polyethylene jackets, armored
• FC-SFTP, 1 pair, solid, PVC jacket
• FC-SFTP, 1 pair, solid, polyethylene jacket
• FTP, 1 pair, stranded (patch), PVC jacket
• PA-STP, 1 pair, stranded (patch), PVC jacket
• SFTP, 1 pair, stranded (patch), polyurethane jacket
• SFTP, 1 pair, stranded (patch), FR-LSZH
• L2/FIP-SFTP, 1 pair, stranded (patch), FR-LSZH
Installation accessories
Tools
Racks and cabinets
Power Distribution Units
Wiring Ducts and Trunking
Access floors
Wire Mesh Cable Trays and CombiRack System
Production shutdown
|
|

Unshielded Twisted Pair Cable (UTP), Category 6, 24 pairs, Solid, Indoor,
23 AWG, FR-PVC
 |
|
1 - Jacket
2 - Bunch of 4 solid twisted pairs
3 - Central strength member
|
Specifications:
Meets IEC 61156, TIA/EIA-568 requirements
The cable meets IEC 60332-1, UL 1581 VW-1 fire safety standards
|
Description:
Unshielded Copper cable, 24 pairs, category 6, solid, consists of 6 unshielded (UTP) bunches of 4 pairs each with spacer. Bunches with spacer are cabled and jacketed with FR-PVC compound.
Cable is used for indoor installation. The multi-cable structure design is optimal for interconnection of telecommunication cabinets in data-centers and alike. The indoor backbone cable is used for high bandwidth digital applications with low BER, high data rates, interconnections in digital multiplex equipment.
|
Materials:
Conductive material: bare copper
Conductor insulation: PO
The cable jacket: FR-PVC
The bunch jacket: FR-PVC
|
Technical characteristics:
Conductor diameter: 23 AWG
Insulated conductor diameter: 1.00 mm (0.04")
Bunch diameter: 6.7 mm (0.26")
Outer cable diameter: 21.7 mm (0.85")
Pulling strength: 200 N max.
Jacket thickness: 0.4 mm (0.015")
Minimum bend radius: 430 mm (16.93")
Operating temperature: -30°C - +60°C (-22°F - +140°F)
Weight per 1000 ft (304.8 m): 267.6 lbs (121.4 kg)
Standard package: 500 m (1640 ft)
|
Electrical characteristics:
| Frequency, MHz |
RL |
Attenuation, dB |
NEXT, dB |
PSNEXT, dB |
ELFEXT, dB |
PSELFEXT, dB |
| 1.0 |
22.0 |
2.0 |
78.0 |
75.0 |
93.0 |
90.0 |
| 4.0 |
25.0 |
3.7 |
69.0 |
66.0 |
93.0 |
90.0 |
| 10.0 |
28.0 |
5.7 |
63.0 |
60.0 |
83.0 |
80.0 |
| 20.0 |
28.0 |
8.1 |
59.0 |
56.0 |
83.0 |
80.0 |
| 30.0 |
27.0 |
10.0 |
56.0 |
53.0 |
73.0 |
70.0 |
| 100.0 |
24.0 |
19.0 |
48.0 |
45.0 |
66.0 |
63.0 |
| 150.0 |
22.0 |
23.6 |
46.0 |
43.0 |
63.0 |
60.0 |
| 200 |
21.0 |
27.7 |
44.0 |
41.0 |
61.0 |
58.0 |
| 250 |
20.0 |
31.4 |
41.0 |
38.0 |
58.0 |
55.0 |
| Conductor DC resistance |
73 Ohm/km (117.53 Ohm/mile) |
| DC Resistance Unbalance |
2% max. |
| Impedance |
100 Ohm |
| Resistance at the frequency of 1-1200 MHz |
100±5 Ohm |
| Capacitive unbalance |
1,2 pF/m (0.36 pF/ft) max. |
| Dielectric strength |
700 V/min |
| Propagation velocity |
68% |
| Propagation delay skew |
35 ns/100 m (12.25 ns/100 ft) max. |
| Insulation resistance |
5 GOhm/km (8 GOhm/mile) |
Ordering
| UTP24-C6-SOLID-INDOOR |
Unshielded twisted pair cable (UTP), 24 pairs, category 6, solid, indoor, FR-PVC |
|
|