Catalog

Twisted Pair Cable (UTP), 2 pairs, Category 5, Solid, LSZH

Specifications:
Meets TIA/EIA-568-B.2 requirements
Fire protection - UL444, UL1581

Description:
Unshielded copper cable, 2 pairs, category 5, solid.
Cable is used for indoor horizontal installation in LAN.

Materials:
Conductive material: wire made of soft annealed electrolytic copper.
Conductor insulation: high-density polyethylene (HDPE).
The cable jacket: LSZH (low smoke zero halogen compound).

Technical characteristics:
Conductor diameter (core): 0.5 mm (24 AWG)
Insulated conductor diameter: 0.88 mm
Outer cable diameter: 4.6 mm
Jacket thickness: 0.5 mm
Minimum bend radius: 4 outer cable diameters
Conductor elongation: 14% minimum
Rip cord breaking strength: 10 kg
Installation temperature: -5C - +40C
Operating temperature: -20C - +75C
Cable weight per 1 km: 18 kg
Standard package: 500 m

Electrical characteristics:
Frequency, MHz RL Attenuation, dB NEXT, dB PSNEXT, dB ELFEXT, dB PSELFEXT, dB
0.772   1.8 67.0 64.0    
1.0 20.0 2.0 65.3 62.3 63.8 60.8
4.0 23.0 4.0 56.3 53.3 51.7 48.7
8.0 24.5 5.8 51.8 48.8 45.7 42.7
10.0 25.0 6.5 50.3 47.3 43.8 40.8
16.0 25.0 8.2 47.3 44.3 39.7 36.7
20.0 25.0 9.3 45.8 42.8 37.7 34.7
25.0 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17.0 38.4 35.4 27.8 24.8
100.0 20.1 22.0 35.3 32.3 23.8 20.8


Conductor resistance at 20°C (68°F) 9.38 Ohm/100 m (2.9 Ohm/100 ft)
DC Resistance Unbalance 5%
Pair-to-Ground Capacitance Unbalance 330 pF/100 m (101 pF/100 ft)
Impedance 0.772-100 MHz 85-115 Ohm
Mutual Capacitance 5.6 nF/m (1.7 nF/ft)
Spark Test 2.5 kV


Ordering
UTP2-C5e-SOLID-LSZH Unshielded Twisted Pair Cable (UTP), 2 pairs, Category 5, Solid, Indoor, LSZH