Catalog

Twisted Pair Cable (UTP), 4 pairs x 2, Category 5e, Solid, PVC

Twisted Pair Cable (UTP), 4 pairs x 2, Category 5e, Solid, PVC 1 - Copper Conductor
2 - HDPE Insulation
3 - Ripcord
4 - Jacket
5 - Web

Specifications:
Meets TIA/EIA 568-B.2 requirements
Fire protection - CM
The cable meets UL 444/UL 1581 fire safety standard

Description:
Unshielded Copper cable, 4 pairs x 2 cables (duplex assembly), category 5e, solid
Cable is used for indoor installation
Application: Horizontal communication cable

Materials:
Conductive material: wire made of soft annealed bare copper
Conductor insulation: HDPE
The cable jacket: PVC (polyvinyl chloride)

Technical characteristics:
Conductor diameter: 0.5 mm (0.019") (24 AWG)
Insulated conductor diameter: 0.9 0.02 mm (0.035" 0.008")
Outer cable diameter: 5.1 0.02 mm (0.2" 0.008")
Jacket thickness: 0.5 0.05 mm (0.0197" 0.002")
Minimum bend radius: 4 outer cable diameters
Conductor elongation: 15% minimum
Rip cord has a breaking strength of 6.9 kg (60 N)
Installation temperature: -5C - +40C (+23F - +104F)
Operating temperature: -20C - +75C (-4F - +167F)
Weight per 1000 ft (304.8 m): 19.8 kg (43.7 lbs)
Standard package: 500 m (1640 ft)

Electrical characteristics
Frequency, MHz RL Attenuation, dB NEXT, dB PSNEXT, dB ELFEXT, dB PSELFEXT, dB
1.0 20.0 2.0 65.3 62.3 63.8 60.8
4.0 23.0 4.0 56.3 53.3 51.7 48.7
8.0 24.5 5.8 51.8 48.8 45.7 42.7
10.0 25.0 6.5 50.3 47.3 43.8 40.8
16.0 25.0 8.2 47.3 44.3 39.7 36.7
20.0 25.0 9.3 45.8 42.8 37.7 34.7
25.0 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17.0 38.4 35.4 27.8 24.8
100.0 20.1 22.0 35.3 32.3 23.8 20.8


Conductor resistance at 20°C (68°F) 9.38 Ohm/100 m (2.9 Ohm/100 ft)
DC Resistance Unbalance 5%
Pair-to-Ground Capacitance Unbalance 330 pF/100 m (101 pF/100 ft)
Impedance 0.772-100 MHz 100 15 Ohm
Mutual Capacitance 5.6 nF/m (1.7 nF/ft)
Spark Test 2.5 kV

Ordering
UTP4x2-C5E-SOLID-INDOOR-GY Unshielded Twisted Pair Cable (UTP), 4 pairs x 2, Category 5, Solid, Indoor, PVC