COMPONENTS OF STRUCTURED CABLING SYSTEMS

   
 

Patch Panels

Work Area Outlets

Keystone Jacks

Modular Plug

Cross Connection

Fiber Optic

Cable Manager

Patch Cords

Cable

Installation Accessories

Tools

Racks and Cabinets

Power Distribution Units

Wiring Ducts and Trunking

Access Floors

Floor coatings

Substructure

General information

Wire Mesh Cable Trays and
CombiRack System

Production Shutdown



 
Catalog


Calcium Sulphate Access Floor Comfort

NORTEC comfort floor system combines all the advantages of a raised floor system with sub-floor heating. This solution offers great freedom to planners and architects, as there is no need for radiators. If the room gets too warm, NORTEC comfort can also be used to cool the room. As there is no drying time for the NORTEC comfort floor system, it is immediately ready for use after installation.

Range of use
Training and research rooms
Office and designing areas
Commercial and private residential constructions
Renovation projects
Projects with short construction times

Special features
The performance ratings can be matched to the particular project
Heating and cooling is possible

Floor coverings
Textile coverings
Elastic coverings
STONEline
Ceramic, Natural stone, Artificial stone

NORTEC comfort MX44-AL-C
Heating:
Heat-flow density (without floor covering): 85 W/m2
Excess temperature of heating agent (DIN 4725-4): 17.2 K
Surface temperature: 84.2°F (29°C)
Water content: 0.058 l/rm
Temperature lag Rė, floor covering [m2K/W] (Reference values):
Carpet 0.07 – 0.23
Ceramic tiles 0.02
PVC 0.01
Active area approx. 75%

NORTEC comfort MX44-AL-S
Heating:
Heat-flow density (without fl oor covering): 85 W/m²
Excess temperature of heating agent (DIN 4725-4): 15.5 K
Surface temperature: 84.2°F (29°C)
Water content: 0.058 l/rm
Temperature lag Rė, fl oor covering [m²K/W] (Reference values):
Carpet 0.07 – 0.23
Ceramic tiles 0.02
PVC 0.01
Active area approx. 75%

System specifications
System designation NORTEC comfort
Type MX44-AL-C MX44-AL-S
Panel/material Calcium sulphate panel with factory-installed heating and cooling lines,
aluminum foil on bottom side
with 0.4” (10 mm) calcium sulphate panel on top side for thermal distribution with natural stone on top side for thermal distribution
Dimensions 600 x 600 mm (23.6” x 23.6”)
Panel thickness 44 mm (1.7”)
System weight1 62 kg/m2 (12.7" lbs/ft2) 70 kg/m2 (14.3" lbs/ft2)
Substructure with construction heights > 500 mm (19.7”) Steel pedestals RO stringer
Construction height2 28 – 1450 mm (1.1” – 57.1”)
Load capacity rating (Nominal load) See "STATICS" supplement
Fireproofing3 Building Material Class of the panel A1 (non-combustible) F30 / REI 30
Heating capacity 85 W/m2 (7.9 W/ft2)
Permissible system pressure <= 8.3 bar
Suitability of coverings Textile coverings, Elastic coverings STONEline

1) Floor height 150 mm (5.9”) (FFH), without covering
2) Clear height, special heights available on request
3) According to DIN 4102 / EN 13 501

 

 
e-mail: info@hyperline.com
Copyright © 2003-2011 HYPERLINE® Registered Trade-mark; used under license

TERMS AND CONDITIONS OF SALE
Rambler's Top100