Protection function


Code: R
Name: AUEC-M30
Parameter: refer to sheet


Surge protective device
AUEC-M30 Performance index Parameter
Rated voltage 250VAC 50/60Hz
Rated load current Ir 16A
Max. Power Pmax 4000W
Max. Continuous operating voltage Uc 320VAC
Measured limiting voltage Ur <1000V
Nominal discharge current (8/20 µS)In 10KA
Voltage protection level Up <1000V
Responce time tA <25nS
Protection mode L-N L-PE N-PE
Polarity indicator Yellow LED
Lightning protection Green LED
Earth indicator Red LED
Alternative filtration Highly efficient
Insulation resistance Ris >100MΩ
Fire resistance Up to UL94V-0
Environment temperature -40°C - +70°C
Relative humidity ≥95%



Code: F
Name: AUEC A20-C2*
Parameter: refer to sheet

Replaceable surge protection component
Performance index A20-C2 A20-C2*
Rated voltage 250VAC 50/60Hz
Max. Persist work voltage 300VAC
Nominal discharge current (8/20 µS)In 10KA
Residual voltage (8/20 µS)Ur <1000V
Responce time tA <25nS
Protect mode L/N-PE
Invalidation indicator No Yes
Insulating resistance >10GΩ
Allowed working temperature -40°C - +80°C
Relative humidity ≥95%



Code: A
Name: MB3306
Parameter: refer to sheet

Digital AC amperemeter
Performance index MB3306 MB3307
Max. input AC 16A/32A AC 3x16A/32A
Full measurement AC 16A/32A AC 16A/32A
Accuracy ±1.0%+2Digit
Resolution 200mA
Frequency range 50-60Hz
Digit display 2
Display Red LED
Overload alarm alarm, LED flashes alarm, LED flashes
L1, L2, and L3 light
Power supply 125/250VAC 3-Phase Electricity



Code: T
Name: AUEC-M01
Parameter: refer to sheet
Code: N
Name: AUEC-M01
Parameter: refer to sheet

Surge protector for network and telephone
Performance index AUEC-M01 AUEC-M03
Voltage Uc 180V 5V
Nominal discharge current (8/20 µS)In 5KA 5KA
Voltage protection level (10/700 µS)Up <400V <30V
Responce time tA <10nS <10nS
Data transmission speed Bit/s >10M >10M
Insertion loss dB <0.5dB <0.5dB
Protection cable core 3.4 1.2.3.6
Tie-in modality RJ11 RJ45

 

 