COMPONENTS OF STRUCTURED CABLING SYSTEMS

   
 

Patch Panels

Work Area Outlets

Keystone Jacks

Modular Plugs

Cross Connection

Fiber Optic

Cable Managers

Patch Cords

Cables

Installation Accessories

Tools

Racks and Cabinets

Power Distribution Units

SHT

SHT-CT

SHT-NM

SHT-NM31

Type A
Type B
Type C
Type D

SHT-NM41/51

Type A
Type B
Type C
Type D

SHT-NM20

SHT-NM30

Type A
Type C
Type D

SHT-NM40/50

Type A
Type C
Type D

Introduction of modules

Wiring Ducts and Trunking

Access Floors

Wire Mesh Cable Trays and
CombiRack System

Production Shutdown



 
Catalog


SHT-NM30 Basic Introduction




Main Characteristics of SHT-NM30
Remotely monitoring, controlling and managing function:
Keep the original state;
Set the limiting value to alarm;
System automatic alarm;
Daisy-chain;
Record the alarm;
User management

Alarming Methods of Hyperline SHT-NM:
The indicator on NM controlling panel flashes and the buzzer alarms;
The indicator on the Web interface flashes and the buzzer alarms;
Automatically send E-mail to system administrator

Software system:
Windows desktop controlling software system is single user operating system which need install and access by:
RS232;
TCP/IP




SHT-NM30 Technical Performance Form
Main function Technical instruction Product classification
Monitor Control
A C D
Monitoring Total load current + + +
Load current of each outlet     +
On/Off state of each outlet   + +
System operating state + + +
Temperature/Humidity + + +
Controlling On/Off of each outlet   + +
Set the interval time of outlets' sequential on/off   + +
Set the on/off time of each outlet   + +
Keep the original state Keep the original state of each outlet when reset   + +
Set the limiting value to alarm The limiting range of total load current + + +
The limiting range of the load current of each outlet     +
The limiting range of temperature and humidity + + +
System automatic alarm The total load current exceeds the limiting value + + +
The load current of individual outlet exceeds the limiting value     +
Temperature/Humidity exceeds the limiting value      
System goes wrong + + +
Alarming method The indicator on NM controlling panel flashes and the buzzer alarms
The indicator on the PC interface flashes and the buzzer alarms
Automatically send E-mail to system administrator
Daisy-chain Daisy-chain 10 pcs at most
Log record Alarming record can be queried
User management Set use's right
Software system In WINDOWS system (single user operating system)
Accessing method By TCP/IP
By RS232


Input/Outlet Characteristics
Main function Item Parameter
Input characteristic Rated input voltage 110/220VAC 50/60 Hz
Input standard IEC60309 industrial plug/IP44
Cable length 3m (9.8 ft)
Max load current 32A
Outlet characteristic Outlet socket standard
Outlet quantity 8
On/Off state of each outlet LED displays
Rated outlet voltage 110/220VAC
Max total load current 32A
Sensor port Temperature/Humidity sensor port 1
Mounting method Horizontal Occupying 1U rack space
Case color Color Black
Fitting COM9/RJ45-G2 connecting line 2m (6.6 ft)
RJ45/RJ45-M2 connecting line 2m (6.6 ft)
Driver CD (one piece)
Instruction one set
Optional fitting Sensor Temperature/Humidity sensor
COM9/RJ45-B2 connecting line 2m (6.6 ft)

 

 
e-mail: info@hyperline.com
Copyright © 2003-2011 HYPERLINE® Registered Trade-mark; used under license